PURPOSE: To compare signal-to-noise ratios (SNRs) and T*(2) maps at 3 T and 7 T using 3D cones from in vivo sodium images of the human knee. MATERIALS AND METHODS: Sodium concentration has been shown to correlate with glycosaminoglycan content of cartilage and is a possible biomarker of osteoarthritis. Using a 3D cones trajectory, 17 subjects were scanned at 3 T and 12 at 7 T using custom-made sodium-only and dual-tuned sodium/proton surface coils, at a standard resolution (1.3 x 1.3 x 4.0 mm(3)) and a high resolution (1.0 x 1.0 x 2.0 mm(3)). We measured the SNR of the images and the T*(2) of cartilage at both 3 T and 7 T. RESULTS: The average normalized SNR values of standard-resolution images were 27.1 and 11.3 at 7 T and 3 T. At high resolution, these average SNR values were 16.5 and 7.3. Image quality was sufficient to show spatial variations of sodium content. The average T*(2) of cartilage was measured as 13.2 +/- 1.5 msec at 7 T and 15.5 +/- 1.3 msec at 3 T. CONCLUSION: We acquired sodium images of patellar cartilage at 3 T and 7 T in under 26 minutes using 3D cones with high resolution and acceptable SNR. The SNR improvement at 7 T over 3 T was within the expected range based on the increase in field strength. The measured T*(2) values were also consistent with previously published values. 2010 Wiley-Liss, Inc.
PURPOSE: To compare signal-to-noise ratios (SNRs) and T*(2) maps at 3 T and 7 T using 3D cones from in vivo sodium images of the human knee. MATERIALS AND METHODS:Sodium concentration has been shown to correlate with glycosaminoglycan content of cartilage and is a possible biomarker of osteoarthritis. Using a 3D cones trajectory, 17 subjects were scanned at 3 T and 12 at 7 T using custom-made sodium-only and dual-tuned sodium/proton surface coils, at a standard resolution (1.3 x 1.3 x 4.0 mm(3)) and a high resolution (1.0 x 1.0 x 2.0 mm(3)). We measured the SNR of the images and the T*(2) of cartilage at both 3 T and 7 T. RESULTS: The average normalized SNR values of standard-resolution images were 27.1 and 11.3 at 7 T and 3 T. At high resolution, these average SNR values were 16.5 and 7.3. Image quality was sufficient to show spatial variations of sodium content. The average T*(2) of cartilage was measured as 13.2 +/- 1.5 msec at 7 T and 15.5 +/- 1.3 msec at 3 T. CONCLUSION: We acquired sodium images of patellar cartilage at 3 T and 7 T in under 26 minutes using 3D cones with high resolution and acceptable SNR. The SNR improvement at 7 T over 3 T was within the expected range based on the increase in field strength. The measured T*(2) values were also consistent with previously published values. 2010 Wiley-Liss, Inc.
Authors: Andrew J Wheaton; Arijitt Borthakur; Erik M Shapiro; Ravinder R Regatte; Sarma V S Akella; J Bruce Kneeland; Ravinder Reddy Journal: Radiology Date: 2004-06 Impact factor: 11.105
Authors: D G Disler; T L Peters; S J Muscoreil; L M Ratner; W A Wagle; J P Cousins; M D Rifkin Journal: AJR Am J Roentgenol Date: 1994-10 Impact factor: 3.959
Authors: S K Hilal; A A Maudsley; J B Ra; H E Simon; P Roschmann; S Wittekoek; Z H Cho; S K Mun Journal: J Comput Assist Tomogr Date: 1985 Jan-Feb Impact factor: 1.826
Authors: Stefan Haneder; Vladimir Juras; Henrik J Michaely; Xeni Deligianni; Oliver Bieri; Stefan O Schoenberg; Siegfried Trattnig; Štefan Zbýň Journal: Eur Radiol Date: 2013-10-02 Impact factor: 5.315
Authors: Fernando E Boada; Yongxian Qian; Edwin Nemoto; Tudor Jovin; Charles Jungreis; S C Jones; Jonathan Weimer; Vincent Lee Journal: Transl Stroke Res Date: 2012-05-04 Impact factor: 6.829