Literature DB >> 20675063

Comparison of liver tumor motion with and without abdominal compression using cine-magnetic resonance imaging.

Cynthia L Eccles1, Ritesh Patel, Anna K Simeonov, Gina Lockwood, Masoom Haider, Laura A Dawson.   

Abstract

PURPOSE: Abdominal compression (AC) can be used to reduce respiratory liver motion in patients undergoing liver stereotactic body radiotherapy. The purpose of the present study was to measure the changes in three-dimensional liver tumor motion with and without compression using cine-magnetic resonance imaging. PATIENTS AND METHODS: A total of 60 patients treated as a part of an institutional research ethics board-approved liver stereotactic body radiotherapy protocol underwent cine T2-weighted magnetic resonance imaging through the tumor centroid in the coronal and sagittal planes. A total of 240 cine-magnetic resonance imaging sequences acquired at one to three images each second for 30-60 s were evaluated using an in-house-developed template matching tool (based on the coefficient correlation) to measure the magnitude of the tumor motion. The average tumor edge displacements were used to determine the magnitude of changes in the caudal-cranial (CC) and anteroposterior (AP) directions, with and without AC.
RESULTS: The mean tumor motion without AC of 11.7 mm (range, 4.8-23.3) in the CC direction was reduced to 9.4 mm (range, 1.6-23.4) with AC. The tumor motion was reduced in both directions (CC and AP) in 52% of the patients and in a single direction (CC or AP) in 90% of the patients. The mean decrease in tumor motion with AC was 2.3 and 0.6 mm in the CC and AP direction, respectively. Increased motion occurred in one or more directions in 28% of patients. Clinically significant (>3 mm) decreases were observed in 40% and increases in <2% of patients in the CC direction.
CONCLUSION: AC can significantly reduce three-dimensional liver tumor motion in most patients, although the magnitude of the reduction was smaller than previously reported. Copyright Â
© 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20675063     DOI: 10.1016/j.ijrobp.2010.04.028

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  32 in total

Review 1.  Charged-particle therapy for hepatocellular carcinoma.

Authors:  Heath D Skinner; Theodore S Hong; Sunil Krishnan
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

2.  Metabolic syndrome-related hepatocellular carcinoma treated by volumetric modulated arc therapy.

Authors:  J Klein; L A Dawson; T H Tran; O Adeyi; T Purdie; M Sherman; A Brade
Journal:  Curr Oncol       Date:  2014-04       Impact factor: 3.677

3.  Segmental analysis of respiratory liver motion in patients with and without a history of abdominal surgery.

Authors:  Yasuhiro Shimizu; Shigeyuki Takamatsu; Kazutaka Yamamoto; Yoshikazu Maeda; Makoto Sasaki; Hiroyasu Tamamura; Sayuri Bou; Tomoyasu Kumano; Toshifumi Gabata
Journal:  Jpn J Radiol       Date:  2018-06-20       Impact factor: 2.374

4.  Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.

Authors:  Edward D Brandner; Indrin J Chetty; Tawfik G Giaddui; Ying Xiao; M Saiful Huq
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

Review 5.  Radiotherapy for liver tumors.

Authors:  Florence K Keane; Shyam K Tanguturi; Andrew X Zhu; Laura A Dawson; Theodore S Hong
Journal:  Hepat Oncol       Date:  2015-04-20

Review 6.  Liver-Directed Radiotherapy for Hepatocellular Carcinoma.

Authors:  Florence K Keane; Jennifer Y Wo; Andrew X Zhu; Theodore S Hong
Journal:  Liver Cancer       Date:  2016-05-10       Impact factor: 11.740

7.  Imaged-guided liver stereotactic body radiotherapy using VMAT and real-time adaptive tumor gating. Concerns about technique and preliminary clinical results.

Authors:  Carmen Llacer-Moscardo; Olivier Riou; David Azria; Ludovic Bedos; Norbert Ailleres; Francois Quenet; Philippe Rouanet; Marc Ychou; Pascal Fenoglietto
Journal:  Rep Pract Oncol Radiother       Date:  2016-09-05

8.  Reproducibility of diaphragm position assessed with a voluntary breath-holding device.

Authors:  Shigeyuki Takamatsu; Tsuyoshi Takanaka; Tomoyasu Kumano; Eiichi Mizuno; Satoshi Shibata; Shizuko Ohashi; Yuichi Kurata; Shinichi Ueda; Naoki Hori; Saori Shouji; Kimiya Noto; Hironori Kojima; Osamu Matsui
Journal:  Jpn J Radiol       Date:  2013-03-23       Impact factor: 2.374

9.  Dose escalated liver stereotactic body radiation therapy at the mean respiratory position.

Authors:  Michael Velec; Joanne L Moseley; Laura A Dawson; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-07-08       Impact factor: 7.038

10.  Kilovoltage Imaging of Implanted Fiducials to Monitor Intrafraction Motion With Abdominal Compression During Stereotactic Body Radiation Therapy for Gastrointestinal Tumors.

Authors:  Ellen Yorke; Ying Xiong; Qian Han; Pengpeng Zhang; Gikas Mageras; Michael Lovelock; Hai Pham; Jian-Ping Xiong; Karyn A Goodman
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-11-18       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.