Literature DB >> 20674087

Asymptomatic sustained ventricular fibrillation in a patient with left ventricular assist device.

Mathias C Busch1, Michael Haap, Arnt Kristen, Christian S Haas.   

Abstract

Optimal medical treatment, cardiac resynchronization, and the use of an implantable cardioverter defibrillator are established therapies of severe congestive heart failure. In refractory cases, left ventricular assist devices are more and more used not only as bridging to cardiac transplantation but also as destination therapy. Ventricular arrhythmias may represent a life-threatening condition and often result in clinical deterioration in patients with congestive heart failure. We report a case of asymptomatic sustained ventricular fibrillation with preserved hemodynamics caused by a nonpulsatile left ventricular assist device. Consecutive adequate but unsuccessful discharges of the implantable cardioverter defibrillator were the only sign of the usually fatal arrhythmia, prompting the patient to consult emergency services. Electrolyte supplementation and initiation of therapy with amiodarone followed by external defibrillation resulted in successful restoration of a stable cardiac rhythm after 3.5 hours.
Copyright © 2010 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20674087     DOI: 10.1016/j.annemergmed.2010.05.023

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  11 in total

1.  Bridge to recovery: understanding the disconnect between clinical and biological outcomes.

Authors:  Stavros G Drakos; Abdallah G Kfoury; Josef Stehlik; Craig H Selzman; Bruce B Reid; John V Terrovitis; John N Nanas; Dean Y Li
Journal:  Circulation       Date:  2012-07-10       Impact factor: 29.690

Review 2.  [Patients with implanted ventricular assist devices : Challenge for emergency medicine].

Authors:  M Bunz; C Kerscher; M Foltan; L Rupprecht; B M Graf; Y A Zausig
Journal:  Anaesthesist       Date:  2015-05       Impact factor: 1.041

Review 3.  Ventricular assist devices: pharmacological aspects of a mechanical therapy.

Authors:  O Wever-Pinzon; J Stehlik; A G Kfoury; J V Terrovitis; N A Diakos; C Charitos; D Y Li; S G Drakos
Journal:  Pharmacol Ther       Date:  2012-01-16       Impact factor: 12.310

Review 4.  Management of Ventricular Arrhythmias in Patients with Mechanical Ventricular Support Devices.

Authors:  Chris Healy; Juan F Viles-Gonzalez; Frederic Sacher; James O Coffey; Andre d'Avila
Journal:  Curr Cardiol Rep       Date:  2015-08       Impact factor: 2.931

Review 5.  Left ventricular assist device unloading effects on myocardial structure and function: current status of the field and call for action.

Authors:  Stavros G Drakos; Abdallah G Kfoury; Craig H Selzman; Divya Ratan Verma; John N Nanas; Dean Y Li; Josef Stehlik
Journal:  Curr Opin Cardiol       Date:  2011-05       Impact factor: 2.161

6.  HFA of the ESC Position paper on the management of LVAD supported patients for the non LVAD specialist healthcare provider Part 1: Introduction and at the non-hospital settings in the community.

Authors:  Binyamin Ben Avraham; Marisa Generosa Crespo-Leiro; Gerasimos Filippatos; Israel Gotsman; Petar Seferovic; Tal Hasin; Luciano Potena; Davor Milicic; Andrew J S Coats; Giuseppe Rosano; Frank Ruschitzka; Marco Metra; Stefan Anker; Johann Altenberger; Stamatis Adamopoulos; Yaron D Barac; Ovidiu Chioncel; Nicolaas De Jonge; Jeremy Elliston; Maria Frigeiro; Eva Goncalvesova; Avishay Grupper; Righab Hamdan; Yoav Hammer; Loreena Hill; Osnat Itzhaki Ben Zadok; Miriam Abuhazira; Jacob Lavee; Wilfried Mullens; Sanemn Nalbantgil; Massimo F Piepoli; Piotr Ponikowski; Arsen Ristic; Arjang Ruhparwar; Aviv Shaul; Laurens F Tops; Steven Tsui; Stephan Winnik; Tiny Jaarsma; Finn Gustafsson; Tuvia Ben Gal
Journal:  ESC Heart Fail       Date:  2021-09-14

7.  Ineffective ICD Shocks for Ventricular Fibrillation in a Patient with a Left Ventricular Assist Device: Continuous Flow During the Electrical Storm.

Authors:  Enes Elvin Gul; Mohammad Melhem; Sohaib Haseeb; Rifat Al Harach; Osama Al Amudi
Journal:  J Atr Fibrillation       Date:  2018-06-30

8.  ICD shocks in LVAD patients are not associated with increased subsequent mortality risk.

Authors:  Aswini Kumar; Varun Tandon; David M O'Sullivan; Edmond Cronin; Jason Gluck; Jeffrey Kluger
Journal:  J Interv Card Electrophysiol       Date:  2019-09-10       Impact factor: 1.900

9.  Heart monitoring using left ventricle impedance and ventricular electrocardiography in left ventricular assist device patients.

Authors:  Keun Her; Chi Bum Ahn; Sung Min Park; Seong Wook Choi
Journal:  Biomed Eng Online       Date:  2015-03-21       Impact factor: 2.819

Review 10.  Algorithms to guide ambulance clinicians in the management of emergencies in patients with implanted rotary left ventricular assist devices.

Authors:  Christopher T Bowles; Rachel Hards; Neil Wrightson; Paul Lincoln; Shishir Kore; Laura Marley; Jonathan R Dalzell; Binu Raj; Tracey A Baker; Diane Goodwin; Petra Carroll; Jane Pateman; John J M Black; Paul Kattenhorn; Mark Faulkner; Jayan Parameshwar; Charles Butcher; Mark Mason; Alexander Rosenberg; Ian McGovern; Alexander Weymann; Carl Gwinnutt; Nicholas R Banner; Stephan Schueler; Andre R Simon; David W Pitcher
Journal:  Emerg Med J       Date:  2017-11-10       Impact factor: 2.740

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.