Literature DB >> 20673473

The "over the core wire" technique for detachable coil retrieval.

T Abe1, M Hirohata, N Tanaka, K Kojima, K Fujimoto, H Nishimura, M Shigemori, N Hayabuchi, A M Norbash.   

Abstract

SUMMARY: We report four cases of malpositioned detachable coil retrieval. In all cases, the malpositioned coils were retrieved without additional neurological deficits. The stretched core wire was grasped with a fixed-loop snare (Gooseneck microsnare), and the detachable coil was retrieved using an over the core wire technique with a hydrophilic microcatheter.

Entities:  

Year:  2001        PMID: 20673473     DOI: 10.1177/15910199980040S140

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  1 in total

1.  Coil migration, malposition, stretching and retrieval.

Authors:  T Abe; M Hirohata; N Tanaka; Y Uchiyama; H Morimitsu; K Kojima; N Hayabuchi
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

  1 in total