Rationale and design of the Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE): interim analysis at 30 days of the first 180 patients enrolled.

D Böckler1, R Fitridge, Y Wolf, P Hayes, P G Silveira, F Numan, V Riambau.   

Abstract

AIM: The Endurant Stent Graft Natural Selection Global Postmarket Registry (ENGAGE) is a long-term 1200-patient multicenter prospective study initiated to augment the knowledge base (poolable and comparable) about endovascular aortic repair (EVAR) in a real-world population implanted with a single latest-generation stent graft system (Endurant). With enrollment ongoing at 80 high-volume sites, the registry has limited inclusion/exclusion criteria or procedural specification. Technical and clinical data will be reported through 5 years.
METHODS: An interim analysis was performed on investigator-reported data for the first 180 patients enrolled. These patients were asymptomatic elderly males (92.1%) with considerable comorbidities. For 47.3% of the patients, the American Society of Anesthesiologists risk class was either III or IV. The Endurant stent graft was successfully deployed in 99.4% of patients for elective treatment of abdominal aortic aneurysm.
RESULTS: Through 30 days, the rate of all-cause mortality was 1.7% (N=3), with all 3 deaths classified as procedure-related but not device-related. The rate of secondary endovascular procedures was 1.1%, and the rate of conversion to open repair was 0.6%. At postprocedure and at 30-day follow-up, there were no type I or type III endoleaks and no instances of stent graft kinking, thrombosis, or occlusion. ENGAGE represents the largest real-world registry for any single EVAR stent graft.
CONCLUSION: The interim results through 30 days of the first 180 patients enrolled are promising. Longer-term follow-up for more patients will be reported.

Entities:  

Mesh:

Year:  2010        PMID: 20671632

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  2 in total

1.  The Endurant Stent Graft System: 15-month follow-up report in patients with challenging abdominal aortic anatomies.

Authors:  Alexander Hyhlik-Dürr; Tim F Weber; Drossos Kotelis; Fabian Rengier; Johannes Gahlen; Stefanie Böck; Jürgen Köhler; Christoph-M Ratusinski; Dittmar Böckler
Journal:  Langenbecks Arch Surg       Date:  2011-05-25       Impact factor: 3.445

2.  Troubleshooting techniques for the Endurant™ device in endovascular aortic aneurysm repair.

Authors:  George S Georgiadis; George A Antoniou; George Trellopoulos; Efstratios I Georgakarakos; Christos Argyriou; Miltos K Lazarides
Journal:  Cardiovasc J Afr       Date:  2014-09-02       Impact factor: 1.167

  2 in total