Literature DB >> 20670062

Endothelial cell morphologic response to asymmetric stenosis hemodynamics: effects of spatial wall shear stress gradients.

Leonie Rouleau1, Monica Farcas, Jean-Claude Tardif, Rosaire Mongrain, Richard L Leask.   

Abstract

Endothelial cells are known to respond to hemodynamic forces. Their phenotype has been suggested to differ between atheroprone and atheroprotective regions of the vasculature, which are characterized by the local hemodynamic environment. Once an atherosclerotic plaque has formed in a vessel, the obstruction creates complex spatial gradients in wall shear stress. Endothelial cell response to wall shear stress may be linked to the stability of coronary plaques. Unfortunately, in vitro studies of the endothelial cell involvement in plaque stability have been limited by unrealistic and simplified geometries, which cannot reproduce accurately the hemodynamics created by a coronary stenosis. Hence, in an attempt to better replicate the spatial wall shear stress gradient patterns in an atherosclerotic region, a three dimensional asymmetric stenosis model was created. Human abdominal aortic endothelial cells were exposed to steady flow (Re=50, 100, and 200 and tau=4.5 dyn/cm(2), 9 dyn/cm(2), and 18 dyn/cm(2)) in idealized 50% asymmetric stenosis and straight/tubular in vitro models. Local morphological changes that occur due to magnitude, duration, and spatial gradients were quantified to identify differences in cell response. In the one dimensional flow regions, where flow is fully developed and uniform wall shear stress is observed, cells aligned in flow direction and had a spindlelike shape when compared with static controls. Morphological changes were progressive and a function of time and magnitude in these regions. Cells were more randomly oriented and had a more cobblestone shape in regions of spatial wall shear stress gradients. These regions were present, both proximal and distal, at the stenosis and on the wall opposite to the stenosis. The response of endothelial cells to spatial wall shear stress gradients both in regions of acceleration and deceleration and without flow recirculation has not been previously reported. This study shows the dependence of endothelial cell morphology on spatial wall shear stress gradients and demonstrates that care must be taken to account for altered phenotype due to geometric features. These results may help explain plaque stability, as cells in shoulder regions near an atherosclerotic plaque had a cobblestone morphology indicating that they may be more permeable to subendothelial transport and express prothrombotic factors, which would increase the risk of atherothrombosis.

Entities:  

Mesh:

Year:  2010        PMID: 20670062     DOI: 10.1115/1.4001891

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  18 in total

1.  Human brain microvascular endothelial cells resist elongation due to shear stress.

Authors:  Adam Reinitz; Jackson DeStefano; Mao Ye; Andrew D Wong; Peter C Searson
Journal:  Microvasc Res       Date:  2015-02-26       Impact factor: 3.514

2.  Evaluation of the hemodynamics in straight 6-mm and tapered 6- to 8-mm grafts as upper arm hemodialysis vascular access.

Authors:  M Sarmast; H Niroomand-Oscuii; F Ghalichi; E Samiei
Journal:  Med Biol Eng Comput       Date:  2014-08-12       Impact factor: 2.602

3.  Microvascular endothelial cells migrate upstream and align against the shear stress field created by impinging flow.

Authors:  Maggie A Ostrowski; Ngan F Huang; Travis W Walker; Tom Verwijlen; Charlotte Poplawski; Amanda S Khoo; John P Cooke; Gerald G Fuller; Alexander R Dunn
Journal:  Biophys J       Date:  2014-01-21       Impact factor: 4.033

4.  Endothelial cell polarization and orientation to flow in a novel microfluidic multimodal shear stress generator.

Authors:  Utku M Sonmez; Ya-Wen Cheng; Simon C Watkins; Beth L Roman; Lance A Davidson
Journal:  Lab Chip       Date:  2020-11-24       Impact factor: 6.799

5.  Simulations reveal adverse hemodynamics in patients with multiple systemic to pulmonary shunts.

Authors:  Mahdi Esmaily-Moghadam; Bari Murtuza; Tain-Yen Hsia; Alison Marsden
Journal:  J Biomech Eng       Date:  2015-01-29       Impact factor: 2.097

6.  Flow reversal promotes intimal thickening in vein grafts.

Authors:  Yong He; Chessy M Fernandez; Zhihua Jiang; Ming Tao; Kerri A O'Malley; Scott A Berceli
Journal:  J Vasc Surg       Date:  2013-12-15       Impact factor: 4.268

7.  Multiplexed Fluid Flow Device to Study Cellular Response to Tunable Shear Stress Gradients.

Authors:  Maggie A Ostrowski; Eva Y Huang; Vinay N Surya; Charlotte Poplawski; Joseph M Barakat; Gigi L Lin; Gerald G Fuller; Alexander R Dunn
Journal:  Ann Biomed Eng       Date:  2015-11-20       Impact factor: 3.934

8.  Endothelial Cell Biomechanical Responses are Dependent on Both Fluid Shear Stress and Tensile Strain.

Authors:  Daphne Meza; Bryan Musmacker; Elisabeth Steadman; Thomas Stransky; David A Rubenstein; Wei Yin
Journal:  Cell Mol Bioeng       Date:  2019-07-09       Impact factor: 2.321

9.  A non-discrete method for computation of residence time in fluid mechanics simulations.

Authors:  Mahdi Esmaily-Moghadam; Tain-Yen Hsia; Alison L Marsden
Journal:  Phys Fluids (1994)       Date:  2013-08-23       Impact factor: 3.521

10.  Mapping the mechanome of live stem cells using a novel method to measure local strain fields in situ at the fluid-cell interface.

Authors:  Min Jae Song; Susann M Brady-Kalnay; Sara H McBride; Polly Phillips-Mason; David Dean; Melissa L Knothe Tate
Journal:  PLoS One       Date:  2012-09-10       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.