OBJECTIVE: To explore the clinical efficacy and safety of balloon kyphoplasty for the aged osteoporotic vertebral compression fractures.
METHODS: From June 2006 to August 2009, balloon kyphoplasty was performed on 26 patients (30 vertebral bodies), who presented painful vertebral compression fractures. They were 10 males and 16 femals, with an average age of 70 years ranging from 59 to 78 years. The operative segments were 4 cases in T11 vertebraes, T12 in 10, L1 in 12, L2 in 3, L4 in 1. The reduction of compressed vertebrae was displayed by X-ray, and the patients were followed up by observation of the visual analog scale and complications.
RESULTS: All cases had rapid, significant and sustained improvements in postoperative pain following balloon kyphoplasty. Visual analog scale was reduced from (8.6 +/- 0.2) to (2.0 +/- 0.3) points. The anterior and midline vertebral body heights in 30 fractured vertebral bodies increased from pre-operative (18.34 +/- 3.25) mm, (14.36 +/- 2.56) mm up to pro-operative (20.51 +/- 1.34) mm, (19.66 +/- 1.28) mm (P < 0.05) respectively. No severe leakage occured.
CONCLUSION: Balloon kyphoplasty in treatment of osteoporotic vertebral compression fractures can restore the height of fractured vertebra, relieve pain and improve the spinal function with satisfactory clinical outcomes.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20669587

Source DB:  PubMed          Journal:  Zhongguo Gu Shang        ISSN: 1003-0034


  1 in total

Review 1.  The Michel Benoist and Robert Mulholland yearly European Spine Journal Review: a survey of the "surgical research" articles in the European Spine Journal 2014.

Authors:  Robert C Mulholland
Journal:  Eur Spine J       Date:  2015-01-03       Impact factor: 3.134

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.