Literature DB >> 20668344

Two new DOSXYZnrc sources for 4D Monte Carlo simulations of continuously variable beam configurations, with applications to RapidArc, VMAT, TomoTherapy and CyberKnife.

Julio Lobo1, I Antoniu Popescu.   

Abstract

We present two new Monte Carlo sources for the DOSXYZnrc code, which can be used to compute dose distributions due to continuously variable beam configurations. These sources support a continuously rotating gantry and collimator, dynamic multileaf collimator (MLC) motion, variable monitor unit (MU) rate, couch rotation and translation in any direction, arbitrary isocentre motion with respect to the patient and variable source-to-axis distance (SAD). These features make them applicable to Monte Carlo simulations for RapidArc, Elekta VMAT, TomoTherapy and CyberKnife. Unique to these sources is the synchronization between the motion in the DOSXYZnrc geometry and the motion within the linac head, represented by a shared library (either a BEAMnrc accelerator with dynamic component modules, or an external library). The simulations are achieved in single runs, with no intermediate phase space files.

Entities:  

Mesh:

Year:  2010        PMID: 20668344     DOI: 10.1088/0031-9155/55/16/S01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  EGSnrc application for IMRT planning.

Authors:  Sitti Yani; Ilmi Rizkia; Mohamad Fahdillah Rhani; Mohammad Haekal; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-22

2.  Radiological tissue equivalence of deformable silicone-based chemical radiation dosimeters (FlexyDos3D).

Authors:  Yi Du; Ruoxi Wang; Meijiao Wang; Haizhen Yue; Yibao Zhang; Hao Wu; Weihu Wang
Journal:  J Appl Clin Med Phys       Date:  2019-06-11       Impact factor: 2.102

3.  Study of efficiency in five-field and field-by-field intensity modulated radiation therapy (IMRT) plan using DOSXYZnrc Monte Carlo code.

Authors:  Sitti Yani; Indra Budiansah; Mohamad Fahdillah Rhani; Freddy Haryanto
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-27

4.  Electron modulated arc therapy (EMAT) using photon MLC for postmastectomy chest wall treatment I: Monte Carlo-based dosimetric characterizations.

Authors:  Chaoqiong Ma; David Parsons; Mingli Chen; Steve Jiang; Qing Hou; Xuejun Gu; Weiguo Lu
Journal:  Phys Med       Date:  2019-10-10       Impact factor: 2.685

5.  A dosimetric phantom study of dose accuracy and build-up effects using IMRT and RapidArc in stereotactic irradiation of lung tumours.

Authors:  Jan Seppala; Sami Suilamo; Jarmo Kulmala; Pekka Mali; Heikki Minn
Journal:  Radiat Oncol       Date:  2012-05-31       Impact factor: 3.481

Review 6.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

7.  GPU-accelerated Monte Carlo simulation of MV-CBCT.

Authors:  Mengying Shi; Marios Myronakis; Matthew Jacobson; Dianne Ferguson; Christopher Williams; Mathias Lehmann; Paul Baturin; Pascal Huber; Rony Fueglistaller; Ingrid Valencia Lozano; Thomas Harris; Daniel Morf; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2020-12-02       Impact factor: 4.174

8.  3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry.

Authors:  A R Barbeiro; A Ureba; J A Baeza; R Linares; M Perucha; E Jiménez-Ortega; S Velázquez; J C Mateos; A Leal
Journal:  PLoS One       Date:  2016-11-21       Impact factor: 3.240

9.  The accuracy of Acuros XB algorithm for radiation beams traversing a metallic hip implant - comparison with measurements and Monte Carlo calculations.

Authors:  Jarkko Ojala; Mika Kapanen; Petri Sipilä; Simo Hyödynmaa; Maunu Pitkänen
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

10.  Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.

Authors:  Alanah M Bergman; Ermias Gete; Cheryl Duzenli; Tony Teke
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.