Literature DB >> 20667359

Performance of bicuspidized pulmonary allografts compared with standard trileaflet allografts.

Terry Shih1, James G Gurney, Edward L Bove, Eric J Devaney, Jennifer C Hirsch, Richard G Ohye.   

Abstract

BACKGROUND: Pulmonary allografts are commonly used in the reconstruction of the right ventricular outflow tract. However, in pediatric patients, allografts that are small enough are often unavailable. To downsize larger, more readily available conduits, one leaflet can be excised, forming a bicuspid valve. The aim of this study was to assess the intermediate-term durability of bicuspidized allografts compared with standard allografts.
METHODS: Forty-seven patients who received a bicuspidized allograft from 1998 to 2008 were compared with 51 patients who received a standard allograft during the same time period. Outcome measures included need for and timing of reintervention, degree of pulmonary stenosis, insufficiency at most recent follow-up, and survival.
RESULTS: On average, the bicuspidized allograft patients were younger, weighed less, and received smaller valves more frequently placed in a heterotopic position than the standard allograft patients. The mean peak gradient across the conduit and the degree of pulmonary insufficiency at discharge were similar between the comparison groups. No statistical differences in need for or timing of reintervention were observed between the surgical groups.
CONCLUSIONS: Bicuspidized allografts performed similarly to that of standard allografts with regard to the need for reintervention, the development of stenosis or regurgitation, and patient survival. Based on this patient sample, the bicuspidized allograft technique appears to provide an excellent option to expand the availability of small-sized allografts for the reconstruction of the right ventricular outflow tract. Copyright 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20667359     DOI: 10.1016/j.athoracsur.2010.04.072

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  1 in total

1.  Early clinical outcomes of right ventricular outflow tract reconstruction with small caliber bovine jugular vein conduit (Contegra®) in small children.

Authors:  Takashi Kido; Takaya Hoashi; Koji Kagisaki; Toshiki Fujiyoshi; Masataka Kitano; Kenichi Kurosaki; Isao Shiraishi; Toshikatsu Yagihara; Yoshiki Sawa; Hajime Ichikawa
Journal:  J Artif Organs       Date:  2016-05-28       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.