Literature DB >> 20664843

Effect of surface topography of implant abutments on retention of cemented single-tooth crowns.

Tomie Nakakuki de Campos1, Lena Katekawa Adachi, Karen Miashiro, Hideki Yoshida, Rosemary Sadami Shinkai, Pedro Tortamano Neto, Maria Luiza Moreira Arantes Frigerio.   

Abstract

This study investigated whether surface topography affects the retentive strength of cemented full crowns, comparing the effects of standard machined, sandblasted, and grooved implant abutments. Five metallic crowns per abutment type were cast and cemented with zinc phosphate. After 24 hours, the specimens were submitted to a tensile test. The retentive strength of the cemented crowns was affected by abutment surface topography. The sandblasted and grooved surface groups had approximately 2.4 times greater mean uniaxial retentive strength than the machined surface group (P < .001). The retentive strength of the sandblasted and grooved abutments was similar, despite marked differences in surface profiles and roughness parameters.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20664843

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  5 in total

1.  Evaluation of the Effect of Axial Wall Modification and Coping Design on the Retention of Cement-retained Implant-supported Crowns.

Authors:  Reza Derafshi; Ahmad Hasan Ahangari; Kianoosh Torabi; Mitra Farzin
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2015-03-04

2.  Effect of Surface Modifications on the Retention of Cement-retained Implant Crowns under Fatigue Loads: An In vitro Study.

Authors:  R Ajay; K Suma; Seyed Asharaf Ali; Jambai Sampath Kumar Sivakumar; V Rakshagan; V Devaki; K Divya
Journal:  J Pharm Bioallied Sci       Date:  2017-11

3.  Effect of Implant Abutment Acid Etching on the Retention of Crowns Luted with Different Cements: An In Vitro Comparative Evaluation.

Authors:  R Ajay; V Rakshagan; M Kamatchi; A SelvaBalaji; Jambai Sampath Kumar Sivakumar; M Senthil Kumar
Journal:  J Pharm Bioallied Sci       Date:  2019-05

4.  Geometry of Implant Abutment Surface Improving Cement Effectiveness: An In vitro Study.

Authors:  Aradhana Rathod; Mohammad Jalaluddin; Trupti Jagannath Devadiga; Shruti Jha; Khaled M Alzahrani
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10

5.  Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study.

Authors:  Monika Bjelopavlovic; Michael Weyhrauch; Herbert Scheller; Stefan Wentaschek; Karl Martin Lehmann
Journal:  Materials (Basel)       Date:  2022-10-07       Impact factor: 3.748

  5 in total