Literature DB >> 20664842

Prognosis of single molar implants: a retrospective study.

Young-Kyun Kim1, Su-Gwan Kim, Pil-Young Yun, Jung-Won Hwang, Mee-Kyoung Son.   

Abstract

The purpose of this study was to evaluate the short- and mid-term prognosis of maxillary and mandibular single molar implants, prosthetic complications, and factors mediating the effects seen on them. Eighty-seven patients were enrolled consecutively in this study and 96 implants were placed into a single molar defect site by one oral and maxillofacial surgeon from March 2004 to December 2006. Primary osseointegration failure developed in two implants and delayed implant failure occurred at four implants. The fraction surviving interval was 97% to 100%, and at the last follow-up observation, the cumulative survival rate was 91.1%. All failed implants occurred in second molar sites, and the failure rate, according to implant site, showed a significant difference. Prosthetic complications, such as screw loosening, showed a significant correlation to the mesiodistal cantilever. Furthermore, crestal bone loss 3 years after loading was 0.2 mm on average and a very stable result was obtained. Based on the results, the risk of failure for maxillary and mandibular single molar implants is high and the possibility of developing prosthetic complications during loading is also high. Therefore, to minimize the cantilever, implants must be placed precisely and followed carefully and maintained for a long period of time.

Entities:  

Mesh:

Year:  2010        PMID: 20664842

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  5 in total

1.  Teeth movement in denture and implant-supported prosthesis influenced by microwave flask systems.

Authors:  Rafael L X Consani; Leonardo G Sonehara; Marcelo F Mesquita; Valentim A R Barão; Conrado R Caetano
Journal:  J Oral Biol Craniofac Res       Date:  2015-07-15

2.  The prognosis of splinted restoration of the most-distal implants in the posterior region.

Authors:  Jong-Bin Lee; Man-Yong Kim; Chang-Sung Kim; Young-Taek Kim
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

3.  Fractures of implant fixtures: a retroscccpective clinical study.

Authors:  Han-Chang Yu; Young-Kyun Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2020-04-25

4.  A retrospective clinical study of single short implants (less than 8 mm) in posterior edentulous areas.

Authors:  Sang-Yun Kim; Jeong-Kui Ku; Hyun-Suk Kim; Pil-Young Yun; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

Review 5.  Clinical reliability of zirconium abutment in implant restorations in the English and Korean literature.

Authors:  Su-Been Yu; Bong-Gyu Song; Kyeong-Jun Cheon; Ju-Won Kim; Young-Hee Kim; Byoung-Eun Yang
Journal:  Maxillofac Plast Reconstr Surg       Date:  2018-09-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.