Literature DB >> 20663391

Angiographical Follow-up Results of Cerebral Aneurysms Treated by Guglielmi Detachable Coil System.

T Hyogo1, T Kataoka, K Hayase, H Nakamura.   

Abstract

SUMMARY: To examine the long term results of endovascular treatment of cerebral aneurysms with the Guglielmi detachable coil (GDC) system, follow- up (F/U) angiography was performed at 6, 12 and 24 months after the procedure. We analyzed 45 cases, 49 procedures of GDC treated cerebral aneurysms from 1997.6. to 2000.5. Follow- up angiography was achieved at 6M 43/45 (96%), 12M 29/33 (87%) and 24M 22/25 (88%). Angiographical changes were found 23/43 (53%) of the cases at 6M F/U. There were angiographical improvements in 12 cases (CP: complete occlusion, NR: neck remnant, PA: partial occlusion, PA-CP; 8, NR-CP; 1, PA-NR; 3) and angiographical worsening in 11 cases (CP-NR; 5, CP-PA; 3, PA-PA; 3) at 6M F/U. Two cases had been demonstrating progressive angiographical worsening at 6M and 12M F/U (CP-NR-PA). No angiographical change was found at 24M F/U. There was no case of hemorrhage or re-hemorrhage after GDC treatment. In cases of side-wall aneurysm, tight packing of the inflow side of the aneurysm and small neck aneurysm were thought to be causes of the angiographical improvements. In patients with wide neck aneurysms with partial occlusion result were angiographic worsening at the F/U. Other factors of angiographical worsening were improper working angle at the procedure and improper follow-up angle at the angiography and the intraluminal clot in the case of ruptured aneurysm.

Entities:  

Year:  2002        PMID: 20663391      PMCID: PMC3627232          DOI: 10.1177/15910199010070S120

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  9 in total

1.  Guglielmi detachable coil embolization of acute intracranial aneurysm: perioperative anatomical and clinical outcome in 403 patients.

Authors:  F Viñuela; G Duckwiler; M Mawad
Journal:  J Neurosurg       Date:  1997-03       Impact factor: 5.115

2.  Bioabsorbable polymeric material coils for embolization of intracranial aneurysms: a preliminary experimental study.

Authors:  Y Murayama; F Viñuela; S Tateshima; J K Song; N R Gonzalez; M P Wallace
Journal:  J Neurosurg       Date:  2001-03       Impact factor: 5.115

3.  Endovascular treatment of ruptured posterior circulation cerebral aneurysms. Clinical and angiographic outcomes.

Authors:  T E Lempert; A M Malek; V V Halbach; C C Phatouros; P M Meyers; C F Dowd; R T Higashida
Journal:  Stroke       Date:  2000-01       Impact factor: 7.914

4.  GDC-system embolization for brain aneurysms - location and follow-up.

Authors:  B Richling; A Gruber; G Bavinzski; M Killer
Journal:  Acta Neurochir (Wien)       Date:  1995       Impact factor: 2.216

Review 5.  Aneurysm geometry: an important criterion in selecting patients for Guglielmi detachable coiling.

Authors:  G M Debrun; V A Aletich; P Kehrli; M Misra; J I Ausman; F Charbel; H Shownkeen
Journal:  Neurol Med Chir (Tokyo)       Date:  1998       Impact factor: 1.742

6.  Electrothrombosis of saccular aneurysms via endovascular approach. Part 2: Preliminary clinical experience.

Authors:  G Guglielmi; F Viñuela; J Dion; G Duckwiler
Journal:  J Neurosurg       Date:  1991-07       Impact factor: 5.115

7.  Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system.

Authors:  M Hayakawa; Y Murayama; G R Duckwiler; Y P Gobin; G Guglielmi; F Viñuela
Journal:  J Neurosurg       Date:  2000-10       Impact factor: 5.115

8.  Endovascular treatment of basilar tip aneurysms using Guglielmi detachable coils: anatomic and clinical outcomes in 73 patients from a single institution.

Authors:  S Tateshima; Y Murayama; Y P Gobin; G R Duckwiler; G Guglielmi; F Viñuela
Journal:  Neurosurgery       Date:  2000-12       Impact factor: 4.654

9.  Delayed aneurysm regrowth and recanalization after Guglielmi detachable coil treatment. Case report.

Authors:  R A Mericle; A K Wakhloo; D K Lopes; G Lanzino; L R Guterman; L N Hopkins
Journal:  J Neurosurg       Date:  1998-07       Impact factor: 5.115

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.