AIMS: To evaluate whether the bladder scanner with real-time pre-scan imaging (RPI) is superior to the conventional bladder scanner in measuring post-void residual urine (PVR) volume.
METHODS: Sixty-seven patients with voiding dysfunction were subjected to PVR volume measurements. The PVR volume was measured three times by two experienced examiners using bladder scanners with (BioCon-500, Mcube Technology, Seoul, Korea) or without (BVI-3000 BladderScan, Verathon, WA) RPI. Immediately after the procedure, urethral catheterization was performed to obtain true volume. The accuracy and variability of measurements were compared between the two devices and correlation coefficients were obtained.
RESULTS: The Pearson correlation coefficients between the PVR volume measured by each device and the true volume were 0.932 for the bladder scanner without RPI and 0.950 for the bladder scanner with RPI. The bladder scanner without RPI tended to overestimate the true volume in moderate volume ranges (>100 ml) by a mean percentage of differences of volume (PDV) of 16.3%, while the bladder scanner with RPI underestimated the true volume in the whole volume range by a mean PDV of -14.1% (P<0.001). Repeated measures ANOVA showed no significant interobserver variability (P=0.977 for the bladder scanner without RPI and P=0.853 for the bladder scanner with RPI) or intraobserver variability (P=0.660 for the bladder scanner without RPI and P=0.271 for the bladder scanner with RPI).
CONCLUSIONS: Our results showed that exact pointing to the bladder prior to actual measurement of bladder volume with RPI seems to reduce the variability of the measured values.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 20658544     DOI: 10.1002/nau.20977

Source DB:  PubMed          Journal:  Neurourol Urodyn        ISSN: 0733-2467            Impact factor:   2.696


  12 in total

Review 1.  Ambulatory urodynamic monitoring: state of the art and future directions.

Authors:  Benjamin Abelson; Steve Majerus; Daniel Sun; Bradley C Gill; Eboo Versi; Margot S Damaser
Journal:  Nat Rev Urol       Date:  2019-05       Impact factor: 14.432

2.  Accuracy and precision of a new portable ultrasound scanner, the Biocon-700, in residual urine volume measurement.

Authors:  Moon Kyoung Cho; Eun Ji Noh; Chul Hong Kim
Journal:  Int Urogynecol J       Date:  2016-12-10       Impact factor: 2.894

3.  Discrepancies in measuring bladder volumes with bedside ultrasound and bladder scanning in the intensive care unit: A pilot study.

Authors:  Donna M Prentice; Carrie Sona; Brian T Wessman; Enyo A Ablordeppey; Warren Isakow; Cassandra Arroyo; Marilyn Schallom
Journal:  J Intensive Care Soc       Date:  2017-11-13

4.  The accuracy of three-dimensional bladder ultrasonography in determining the residual urinary volume compared with conventional catheterisation.

Authors:  Imran K Jalbani; M Hammad Ather
Journal:  Arab J Urol       Date:  2014-07-29

5.  Falsely Elevated Postvoid Residual Urine Volume in Uterine Myoma.

Authors:  Tae Hee Kim; Hyo Sang Kim; Jung Wook Park; Oh Kyung Lim; Ki Deok Park; Ju Kang Lee
Journal:  Ann Rehabil Med       Date:  2017-04-27

6.  Portable Bladder Ultrasound Reduces Incidence of Urinary Tract Infection and Shortens Hospital Length of Stay in Patients With Acute Ischemic Stroke.

Authors:  Shu-Chuan Chen; Pei-Ya Chen; Guei-Chiuan Chen; Su-Yun Chuang; I-Shiang Tzeng; Shinn-Kuang Lin
Journal:  J Cardiovasc Nurs       Date:  2018 Nov/Dec       Impact factor: 2.083

7.  Development and evaluation of automated ultrasonographic detection of bladder diameter for estimation of bladder urine volume.

Authors:  Masaru Matsumoto; Takuya Tsutaoka; Koichi Yabunaka; Mayumi Handa; Mikako Yoshida; Gojiro Nakagami; Hiromi Sanada
Journal:  PLoS One       Date:  2019-09-05       Impact factor: 3.240

8.  False positive bladder scan in ascites with anuria.

Authors:  Sarosh Janardanan; Ahmed E M Moussa; Philip James
Journal:  Clin Case Rep       Date:  2019-07-03

9.  Acupuncture for Chronic Urinary Retention due to Spinal Cord Injury: A Systematic Review.

Authors:  Jia Wang; Yanbing Zhai; Jiani Wu; Shitong Zhao; Jing Zhou; Zhishun Liu
Journal:  Evid Based Complement Alternat Med       Date:  2016-04-13       Impact factor: 2.629

10.  Effect of electroacupuncture on diabetic neurogenic bladder: A randomized controlled trial protocol.

Authors:  Xuke Han; Yang Gao; Shengju Wang; Qiu Chen
Journal:  Medicine (Baltimore)       Date:  2020-04       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.