Literature DB >> 20657866

Accuracy of impression techniques for an implant-supported prosthesis.

Marcelo Antonialli Del'Acqua1, Alejandro Muñoz Chávez, Marco Antonio Compagnoni, Francisco de Assis Molo.   

Abstract

PURPOSE: This in vitro study compared the dimensional accuracy of a stone index and of two impression techniques (squared impression copings and modified squared impression copings) for implant-supported prostheses.
MATERIALS AND METHODS: A master cast with four parallel implant-abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Three groups of impressions were tested (n = 5): index (I), squared (S), and modified squared (MS). The measurement method employed was just one titanium screw tightened to the framework. The measurements (60 gap values) were analyzed using software that received the images from a video camera coupled to a stereomicroscope at 3100 magnification. The results were evaluated statistically (analysis of variance, Holm-Sidak method, α = .05).
RESULTS: The mean abutment/framework interface gaps were: master cast = 31.63 µm; group I = 45.25 µm; group S = 96.14 µm; group MS = 51.20 µm. No significant difference was detected among the index and modified squared techniques (P = .05).
CONCLUSION: Under the limitations of this study, the techniques modified squared and index generated more accurate casts than the squared technique.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20657866

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

2.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Arndt Happe; Markus Schlee; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

3.  Need for a reliable alternative to custom-made Implant Impression trays: An in vitro study comparing accuracy of custom trays versus specialized aluminum stock tray.

Authors:  Mukti Goel; Pankaj Dhawan; Piyush Tandan; Pankaj Madhukar
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep
  3 in total