Microbial contamination of disinfectants used for intermittent self-catheterization.

Harumasa Hakuno1, Mitutaka Yamamoto, Shigeharu Oie, Akira Kamiya.   

Abstract

We investigated the microbial contamination of 0.02% benzalkonium chloride solution used in catheter kits for intermittent self-catheterization. Of 20 samples examined, 12 (60.0%) were contaminated with 8.8 x 10(2)-3.1 x 10(6) colony-forming units (cfu)/mL. The contaminants were Pseudomonas fluorescens, Burkholderia cepacia, and Aeromonas spp. These results showed that 0.02% benzalkonium chloride solution used for the lubrication/disinfection of catheters for self-catheterization is susceptible to contamination. Therefore, the lubricant/disinfectant for catheters for self-catheterization was changed from 0.02% benzalkonium chloride solution to 84-87% glycerin containing 0.02% benzalkonium chloride, and microbial contamination of the latter in catheter kits for self-catheterization was reinvestigated. Of 42 samples, 5 (11.9%) were contaminated with 20-2.0 x 10(4) cfu/mL. However, the rate of contamination of 84-87% glycerin containing 0.02% benzalkonium chloride was significantly lower than that of 0.02% benzalkonium chloride solution (P<0.0001). The contaminant of 84-87% glycerin containing 0.02% benzalkonium chloride was Bacillus spp. in all contaminated samples. In this survey, neither contaminants of 0.02% benzalkonium chloride solution nor the contaminant of 84-87% glycerin containing 0.02% benzalkonium chloride were the causative microbial species of urinary tract infection.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20657069

Source DB:  PubMed          Journal:  Jpn J Infect Dis        ISSN: 1344-6304            Impact factor:   1.362


  4 in total

1.  Type III secretion system and virulence markers highlight similarities and differences between human- and plant-associated pseudomonads related to Pseudomonas fluorescens and P. putida.

Authors:  Sylvie Mazurier; Annabelle Merieau; Dorian Bergeau; Victorien Decoin; Daniel Sperandio; Alexandre Crépin; Corinne Barbey; Katy Jeannot; Maïté Vicré-Gibouin; Patrick Plésiat; Philippe Lemanceau; Xavier Latour
Journal:  Appl Environ Microbiol       Date:  2015-01-30       Impact factor: 4.792

2.  Benzalkonium chloride induced corrosive balanoposthitis in a man requiring clean intermittent catheterization.

Authors:  Yo Satoji; Shohei Tobu; Kyohei Matsushita; Kazuma Udo; Mitsuru Noguchi
Journal:  IJU Case Rep       Date:  2021-01-12

3.  Successful cessation of transmitting healthcare -- associated infections due to Burkholderia cepacia complex in a neonatal intensive care unit in a Japanese children's hospital.

Authors:  K Kuzumoto; N Kubota; K Ishii; K Yumoto; Y Ogiso; T Nakamura; T Katsuyama; K Oana; Y Kawakami
Journal:  Eur J Med Res       Date:  2011-12-02       Impact factor: 2.175

4.  Effect of Different Disinfectants on Bacterial Aerosol Diversity in Poultry Houses.

Authors:  Linlin Jiang; Meng Li; Jinxiu Tang; Xiaoyu Zhao; Jianlong Zhang; Hongwei Zhu; Xin Yu; Youzhi Li; Tao Feng; Xingxiao Zhang
Journal:  Front Microbiol       Date:  2018-09-11       Impact factor: 5.640

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.