Literature DB >> 20657018

Evaluation of an open-field autorefractor's ability to measure refraction and hence potential to assess objective accommodation in pseudophakes.

James Stuart Wolffsohn1, Leon Nicholas Davies, Shehzad Anjam Naroo, Phillip Jonathan Buckhurst, George Anthony Gibson, Navneet Gupta, Jennifer Patricia Craig, Sunil Shah.   

Abstract

BACKGROUND: To evaluate the accuracy of an open-field autorefractor compared with subjective refraction in pseudophakes and hence its ability to assess objective eye focus with intraocular lenses (IOLs).
METHODS: Objective refraction was measured at 6 m using the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K open-field autorefractor (five repeats) and by subjective refraction on 141 eyes implanted with a spherical (Softec1 n=53), aspherical (SoftecHD n=37) or accommodating (1CU n=22; Tetraflex n=29) IOL. Autorefraction was repeated 2 months later.
RESULTS: The autorefractor prescription was similar (average difference: 0.09 ± 0.53 D; p=0.19) to that found by subjective refraction, with ∼71% within ± 0.50 D. The horizontal cylindrical components were similar (difference: 0.00 ± 0.39 D; p=0.96), although the oblique (J(45)) autorefractor cylindrical vector was slightly more negative (by -0.06 ± 0.25 D; p=0.06) than the subjective refraction. The results were similar for each of the IOL designs except for the spherical IOL, where the mean spherical equivalent difference between autorefraction and subjective was more hypermetropic than the Tetraflex accommodating IOL (F=2.77, p=0.04). The intrasession repeatability was <0.55 D (95% CI) and intersession repeatability <0.50 D in ≥ 85%.
CONCLUSIONS: The autorefractor gives valid and repeatable measures of pseudophakic eye refraction and hence objective accommodation.

Entities:  

Mesh:

Year:  2010        PMID: 20657018     DOI: 10.1136/bjo.2010.185009

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  4 in total

1.  Validation of the PowerRef 3 for Measuring Accommodation: Comparison With the Grand Seiko WAM-5500A Autorefractor.

Authors:  Alyssa M Gehring; Jennifer X Haensel; Molly K Curtiss; Tawna L Roberts
Journal:  Transl Vis Sci Technol       Date:  2022-10-03       Impact factor: 3.048

2.  Aberrometry Repeatability and Agreement with Autorefraction.

Authors:  Mylan T Nguyen; David A Berntsen
Journal:  Optom Vis Sci       Date:  2017-09       Impact factor: 1.973

3.  Accommodative responses under various viewing conditions in surgical patients with intermittent exotropia: an institutional, retrospective study.

Authors:  Ziyi Qi; Linlin Du; Jun Chen; Xun Xu; Xiangui He; Jun Qiang
Journal:  BMC Ophthalmol       Date:  2022-05-04       Impact factor: 2.086

4.  Uncorrected Refractive Error and Distance Visual Acuity in Children Aged 6 to 14 Years.

Authors:  Robert N Kleinstein; Donald O Mutti; Loraine T Sinnott; Lisa A Jones-Jordan; Susan A Cotter; Ruth E Manny; J Daniel Twelker; Karla Zadnik
Journal:  Optom Vis Sci       Date:  2021-01-01       Impact factor: 2.106

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.