Literature DB >> 20655728

Electrochemical detection of D-dimer as deep vein thrombosis marker using single-chain D-dimer antibody immobilized on functionalized polypyrrole.

S Chebil1, I Hafaiedh, H Sauriat-Dorizon, N Jaffrezic-Renault, A Errachid, Z Ali, H Korri-Youssoufi.   

Abstract

We describe a rapid and sensitive method for detection and quantification of d-dimer which is a biomarker present at elevated concentrations in patients with deep vein thrombosis (DVT) disorders. The method uses an immunosensor based on a single-chain antibody (ScAb) immobilized on a transducer surface and with a densely packed receptor layer. Detection is based on the redox activity of a N-alpha bis(carboxymethyl)-L-lysine (ANTA)/Cu2+ complex attached to a polypyrrole backbone. The resulting hybrid material: polypyrrole ANTA/metal complex/His-tag ScAb was characterized by AFM, surface plasmon resonance (SPR) and differential pulse voltammetry (DPV) for the optimization of the biosensor formation. The biosensor offers a promising template for antibody immobilization and for immunodetection of a specific D-dimer. The biosensor shows a remarkable variation in redox activity of the ANTA/Cu2+ complex after the D-dimer association with a binding constant Kd of 1 ng mL(-1). Electrochemical impedance spectroscopy (EIS) allows monitoring D-dimer association with a linear response between 0.1 ng mL(-1) and 500 ng mL(-1) and a detection limit of 100 pg mL(-1) in PBS is obtained. The biolayer exhibits the same sensitivity for the detection of d-dimer in human patient plasma samples. This assay method is versatile, offers enhanced performance for the evaluation of proteins association and could easily be extended to the detection of other proteins, present in serum human sample.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20655728     DOI: 10.1016/j.bios.2010.06.048

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

1.  Polypyrrole-palladium nanocomposite as a high-efficiency transducer for thrombin detection with liposomes as a label.

Authors:  Ajay Kumar Yagati; Arne Behrent; Vanessa Tomanek; Sachin Ganpat Chavan; Anna Go; Sung Ryul Park; Zhengzhi Jin; Antje J Baeumner; Min-Ho Lee
Journal:  Anal Bioanal Chem       Date:  2021-10-07       Impact factor: 4.142

2.  Multiplexed DNA-Directed Patterning of Antibodies for Applications in Cell Subpopulation Analysis.

Authors:  Molly Kozminsky; Olivia J Scheideler; Brian Li; Nathaniel K Liu; Lydia L Sohn
Journal:  ACS Appl Mater Interfaces       Date:  2021-09-21       Impact factor: 9.229

3.  A Simple, Cost-Effective Sensor for Detecting Lead Ions in Water Using Under-Potential Deposited Bismuth Sub-Layer with Differential Pulse Voltammetry (DPV).

Authors:  Yifan Dai; Chung Chiun Liu
Journal:  Sensors (Basel)       Date:  2017-04-25       Impact factor: 3.576

4.  Detection of 17 β-Estradiol in Environmental Samples and for Health Care Using a Single-Use, Cost-Effective Biosensor Based on Differential Pulse Voltammetry (DPV).

Authors:  Yifan Dai; Chung Chiun Liu
Journal:  Biosensors (Basel)       Date:  2017-03-29

Review 5.  Electrochemical sensing: A prognostic tool in the fight against COVID-19.

Authors:  Sharda Kotru; Martin Klimuntowski; Hashim Ridha; Zakir Uddin; Ali A Askhar; Gurmit Singh; Matiar M R Howlader
Journal:  Trends Analyt Chem       Date:  2021-01-23       Impact factor: 14.908

Review 6.  State of the art of colloidal particles and unique interfaces-based SARS-CoV-2 detection methods and COVID-19 diagnosis.

Authors:  Ebru Saatçi; Satheesh Natarajan
Journal:  Curr Opin Colloid Interface Sci       Date:  2021-05-29       Impact factor: 6.448

Review 7.  Antibodies and antibody-derived analytical biosensors.

Authors:  Shikha Sharma; Hannah Byrne; Richard J O'Kennedy
Journal:  Essays Biochem       Date:  2016-06-30       Impact factor: 8.000