Literature DB >> 20655184

Electrochemical behavior and analytical application of ciprofloxacin using a multi-walled nanotube composite film-glassy carbon electrode.

Lida Fotouhi1, Mahnaz Alahyari.   

Abstract

A simple, rapid and applicable electrochemical method was developed for the determination of ciprofloxacin (Cf) based on a multi-wall carbon nanotubes film-modified glassy carbon electrode (MWCNT/GCE). The constructed electrode (MWCNT/GCE) exhibited excellent electrocatalytic behavior in the oxidation of Cf as evidenced by the enhancement of the oxidation peak current and the shift in the oxidation potential to lower values (by 130 mV) in comparison with the bare GCE. A detailed analysis of cyclic voltammograms and chronoamperograms gave fundamental electrochemical parameters including the electroactive surface coverage (Gamma), the transfer coefficient (alpha), the standard rate constant (k(s)) and diffusion coefficient (D). Under optimized conditions in voltammetric method, the dynamic linear calibration curve for Cf was obtained in the concentration range of 40-1000 micromol/L with the detection limit of 6 micromol/L. The analytical performance of this sensor has been evaluated for detection of the analyte in urine and serum samples. Copyright (c) 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20655184     DOI: 10.1016/j.colsurfb.2010.06.030

Source DB:  PubMed          Journal:  Colloids Surf B Biointerfaces        ISSN: 0927-7765            Impact factor:   5.268


  5 in total

1.  Spectrofluorimetric determination of fluoroquinolones in honey with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone in the presence of β-cyclodextrin.

Authors:  Qinghai Xia; Yaling Yang; Mousheng Liu
Journal:  J Fluoresc       Date:  2013-03-13       Impact factor: 2.217

2.  Simple, fast and environmentally friendly method to determine ciprofloxacin in wastewater samples based on an impedimetric immunosensor.

Authors:  Rafaela Silva Lamarca; Ricardo Adriano Dorledo de Faria; Maria Valnice Boldrin Zanoni; Marcelo Nalin; Paulo Clairmont Feitosa de Lima Gomes; Younès Messaddeq
Journal:  RSC Adv       Date:  2020-01-08       Impact factor: 4.036

3.  Robotic voltammetry with carbon nanotube-based sensors: a superb blend for convenient high-quality antimicrobial trace analysis.

Authors:  Somjai Theanponkrang; Wipa Suginta; Helge Weingart; Mathias Winterhalter; Albert Schulte
Journal:  Int J Nanomedicine       Date:  2015-01-27

4.  A chitosan gold nanoparticles molecularly imprinted polymer based ciprofloxacin sensor.

Authors:  Sandeep G Surya; Shahjadi Khatoon; Abdellatif Ait Lahcen; An T H Nguyen; Boris B Dzantiev; Nazia Tarannum; Khaled N Salama
Journal:  RSC Adv       Date:  2020-03-31       Impact factor: 4.036

5.  Isolation of microorganisms using sub-micrometer constrictions.

Authors:  Nil Tandogan; Pegah N Abadian; Slava Epstein; Yoshiteru Aoi; Edgar D Goluch
Journal:  PLoS One       Date:  2014-06-30       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.