Literature DB >> 20655173

Comparison between different speckle tracking and color tissue Doppler techniques to measure global and regional myocardial deformation in children.

Laurens P Koopman1, Cameron Slorach, Wei Hui, Cedric Manlhiot, Brian W McCrindle, Mark K Friedberg, Edgar T Jaeggi, Luc Mertens.   

Abstract

BACKGROUND: Myocardial deformation parameters obtained by speckle-tracking echocardiography (STE) and color Doppler tissue imaging (CDTI) using two different ultrasound systems and three different software packages were compared.
METHODS: Apical four-chamber, short-axis grayscale, and color Doppler tissue images were prospectively acquired using Vivid 7 and iE33 ultrasound systems in 34 children and then analyzed using EchoPAC and QLAB (STE) and SPEQLE (CDTI).
RESULTS: Measurement of myocardial deformation was feasible for all three modalities. Longitudinal strain (epsilon) measurements showed the lowest intraobserver and interobserver variability (intraobserver and interobserver coefficients of variation, 9% and 8% for EchoPAC, 5% and 6% for QLAB, and 14% and 16% for SPEQLE). In addition, longitudinal epsilon had a small bias and narrow limits of agreement when comparing different techniques. The coefficients of variation of circumferential epsilon by EchoPAC and QLAB were 12% and 11% (intraobserver) and 9% and 13% (interobserver), respectively. Circumferential epsilon by STE had a small systematic bias but relatively narrow limits of agreement. The reproducibility of radial epsilon measurements using STE was low, while CDTI epsilon provided better performance (intraobserver and interobserver coefficients of variation for radial posterior epsilon, 12% and 24% for EchoPAC, 39% and 56% for QLAB, and 12% and 14% for SPEQLE). Radial epsilon was on average 50% lower using QLAB compared with EchoPAC and SPEQLE. Systolic strain rate values obtained by STE were lower compared with CDTI-derived values. The limits of agreement for strain rate values among the three modalities were wide, and intraobserver and interobserver variability was poor for all three modalities.
CONCLUSIONS: Some deformation measurements (e.g., longitudinal and circumferential epsilon) are comparable among different ultrasound machines and software packages, whereas others are significantly different (e.g., radial epsilon and strain rate). This study stresses the need for an industry standard for these techniques. 2010 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20655173     DOI: 10.1016/j.echo.2010.06.014

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  45 in total

1.  Cardiac resynchronization by cardiosphere-derived stem cell transplantation in an experimental model of myocardial infarction.

Authors:  Michael Bonios; Connie Y Chang; Aurelio Pinheiro; Veronica Lea Dimaano; Takahiro Higuchi; Christina Melexopoulou; Frank Bengel; John Terrovitis; Theodore P Abraham; M Roselle Abraham
Journal:  J Am Soc Echocardiogr       Date:  2011-04-20       Impact factor: 5.251

2.  Feasibility and reproducibility of systolic right ventricular strain measurement by speckle-tracking echocardiography in premature infants.

Authors:  Philip Thaler Levy; Mark R Holland; Timothy J Sekarski; Aaron Hamvas; Gautam K Singh
Journal:  J Am Soc Echocardiogr       Date:  2013-07-20       Impact factor: 5.251

Review 3.  Reference Ranges of Left Ventricular Strain Measures by Two-Dimensional Speckle-Tracking Echocardiography in Children: A Systematic Review and Meta-Analysis.

Authors:  Philip T Levy; Aliza Machefsky; Aura A Sanchez; Meghna D Patel; Sarah Rogal; Susan Fowler; Lauren Yaeger; Angela Hardi; Mark R Holland; Aaron Hamvas; Gautam K Singh
Journal:  J Am Soc Echocardiogr       Date:  2015-12-30       Impact factor: 5.251

Review 4.  Transthoracic echocardiography in the evaluation of pediatric pulmonary hypertension and ventricular dysfunction.

Authors:  Martin Koestenberger; Mark K Friedberg; Eirik Nestaas; Ina Michel-Behnke; Georg Hansmann
Journal:  Pulm Circ       Date:  2016-03       Impact factor: 3.017

5.  Feasibility and Reproducibility of Two-Dimensional Wall Motion Tracking (WMT) in Fetal Echocardiography.

Authors:  Christian Enzensberger; Friederike Achterberg; Jan Degenhardt; Aline Wolter; Oliver Graupner; Johannes Herrmann; Roland Axt-Fliedner
Journal:  Ultrasound Int Open       Date:  2017-02

6.  Impact of the Amplatzer atrial septal occluder device on left ventricular function in pediatric patients.

Authors:  Biagio Castaldi; Giuseppe Santoro; Giovanni Di Salvo; Gianpiero Gaio; Maria Teresa Palladino; Fabio D'Aiello; Carola Iacono; Giuseppe Pacileo; Raffaele Calabrò; Maria Giovanna Russo
Journal:  Pediatr Cardiol       Date:  2013-04-17       Impact factor: 1.655

7.  Myocardial function in children after fetal chemotherapy exposure. A tissue Doppler and myocardial deformation imaging study.

Authors:  Mina Mhallem Gziri; Wei Hui; Frédéric Amant; Kristel Van Calsteren; Nelleke Ottevanger; Livia Kapusta; Luc Mertens
Journal:  Eur J Pediatr       Date:  2012-10-05       Impact factor: 3.183

Review 8.  Normal ranges of right ventricular systolic and diastolic strain measures in children: a systematic review and meta-analysis.

Authors:  Philip T Levy; Aura A Sanchez Mejia; Aliza Machefsky; Susan Fowler; Mark R Holland; Gautam K Singh
Journal:  J Am Soc Echocardiogr       Date:  2014-02-26       Impact factor: 5.251

9.  Parametric ultrasound and fluoroscopy image fusion for guidance of left ventricle lead placement in cardiac resynchronization therapy.

Authors:  Aleksandar Babic; Hans Henrik Odland; Olivier Gérard; Eigil Samset
Journal:  J Med Imaging (Bellingham)       Date:  2015-05-13

10.  The Use of Speckle Tracking Echocardiography for Early Detection of Myocardial Dysfunction in Patients with Duchenne Muscular Dystrophy.

Authors:  Anas Taqatqa; John Bokowski; Maytham Al-Kubaisi; Ahmad Khalil; Carlos Miranda; Hamad Alaksham; Ibtihaj Fughhi; Damien Kenny; Karim A Diab
Journal:  Pediatr Cardiol       Date:  2016-07-25       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.