Literature DB >> 20654553

Established cell lines and primary cultures in testing medical devices in vitro.

E Cenni1, G Ciapetti, D Granchi, C R Arciola, L Savarino, S Stea, L Montanaro, A Pizzoferrato.   

Abstract

In testing for the cytotoxicity of medical devices, crucial parameters are the type of cells, the duration of the exposure, the physical form of the device and the method of evaluation. Using cell cultures the changes of cell functions induced by artificial materials may be evaluated. In screening tests the effect of biomaterials on functions common to all cell types is investigated through both continuous lines and primary cultures. In supplementary tests the effect of biomaterials on specific functions is studied, employing cells of the same type of those which will be in contact with the device in vivo. Osteoblasts, either from primary culture or an established line, are used to study the interaction with materials for bone implants. We evaluated whether dental cements affect the replication cycle of osteoblast-like cells MG63. The S phase was inhibited by the cements with a phenolic group, even though to a different extent. Mononuclear cell cultures are used to investigate the immune response, which is important in the host reaction to implant. We investigated whether the chromium ions released in a biological fluid may induce PBMC to produce cytokines involved in bone resorption. Chromium extract did not impair TNFalpha release significantly, but inhibited IL-6 release significantly in stimulated PBMC. Endothelial cell cultures are useful to the evaluation of materials for vascular grafts. We studied the influence of some types of Dacron on endothelial functions. Collagen-coated Dacron decreased significantly the production of 6-keto-prostaglandin F(1alpha). Knitted Dacron caused a significant increase of tissue factor, a significant reduction in PECAM-1 and a significant increase in ELAM-1.

Entities:  

Year:  1999        PMID: 20654553     DOI: 10.1016/s0887-2333(99)00058-2

Source DB:  PubMed          Journal:  Toxicol In Vitro        ISSN: 0887-2333            Impact factor:   3.500


  4 in total

1.  Evaluation of the extraction method for the cytotoxicity testing of latex gloves.

Authors:  Hyun Sook Baek; Ja Young Yoo; Dong Kyun Rah; Dong-Wook Han; Dong Hee Lee; Oh-Hun Kwon; Jong-Chul Park
Journal:  Yonsei Med J       Date:  2005-08-31       Impact factor: 2.759

2.  How Surface Properties of Silica Nanoparticles Influence Structural, Microstructural and Biological Properties of Polymer Nanocomposites.

Authors:  Łukasz Zych; Anna Maria Osyczka; Agnieszka Łacz; Agnieszka Różycka; Wiktor Niemiec; Alicja Rapacz-Kmita; Ewa Dzierzkowska; Ewa Stodolak-Zych
Journal:  Materials (Basel)       Date:  2021-02-10       Impact factor: 3.623

3.  In vitro assessment of the biocompatibility of chemically treated silicone materials with human lens epithelial cells.

Authors:  Elizabeth C Y Kao; Junghee Seo; David J McCanna; Lakshman N Subbaraman; Lyndon W Jones
Journal:  Sci Rep       Date:  2022-03-17       Impact factor: 4.379

4.  A Comparison between Cytotoxicity Induced by Two Resin Based Sealers (2Seal and AH Plus) in Saos-2 and MG-63 Cell Lines.

Authors:  Maryam Ehsani; Ebrahim Zabihi; Hamed Gharouee
Journal:  Int J Mol Cell Med       Date:  2012
  4 in total