INTRODUCTION: There is an obvious need for a better energy source for pulmonary vein (PV) antrum isolation. OBJECTIVE: We investigated the feasibility and safety of electroporation for the creation of PV ostial lesions. METHODS: After transseptal puncture, a custom 7F decapolar 20 mm circular ablation catheter was placed in the PV ostia of 10 pigs. Ablation was performed with a nonarcing, 200 J application delivered between the catheter and an indifferent patch electrode on the lower back. A single pulse was applied for each catheter position, with a maximum of 4 per ostium. Local PV electrogram amplitude and stimulation threshold were measured at multiple locations in both ostia before and directly after ablation, and after 3 weeks survival, using a regular 4 mm mapping catheter. All PV ostia were sectioned, stained, and histologically investigated. RESULTS: The 3-week survival period was uneventful. PV ostial electrogram amplitude decreased and stimulation threshold increased significantly in most ostia. PV angiograms did not show any stenosis during this short follow-up. Histologically, up to 3.5-mm-deep lesions were found. CONCLUSION: Data suggest that electroporation can safely be used to create lesions in a sensitive environment like PV ostia.
INTRODUCTION: There is an obvious need for a better energy source for pulmonary vein (PV) antrum isolation. OBJECTIVE: We investigated the feasibility and safety of electroporation for the creation of PV ostial lesions. METHODS: After transseptal puncture, a custom 7F decapolar 20 mm circular ablation catheter was placed in the PV ostia of 10 pigs. Ablation was performed with a nonarcing, 200 J application delivered between the catheter and an indifferent patch electrode on the lower back. A single pulse was applied for each catheter position, with a maximum of 4 per ostium. Local PV electrogram amplitude and stimulation threshold were measured at multiple locations in both ostia before and directly after ablation, and after 3 weeks survival, using a regular 4 mm mapping catheter. All PV ostia were sectioned, stained, and histologically investigated. RESULTS: The 3-week survival period was uneventful. PV ostial electrogram amplitude decreased and stimulation threshold increased significantly in most ostia. PV angiograms did not show any stenosis during this short follow-up. Histologically, up to 3.5-mm-deep lesions were found. CONCLUSION: Data suggest that electroporation can safely be used to create lesions in a sensitive environment like PV ostia.
Authors: Saurabh Kumar; Chirag R Barbhaiya; Samuel Balindger; Roy M John; Laurence M Epstein; Bruce A Koplan; Usha B Tedrow; William G Stevenson; Gregory F Michaud Journal: J Atr Fibrillation Date: 2015-10-31
Authors: Chance M Witt; Alan Sugrue; Deepak Padmanabhan; Vaibhav Vaidya; Sarah Gruba; James Rohl; Christopher V DeSimone; Ammar M Killu; Niyada Naksuk; Joanne Pederson; Scott Suddendorf; Dorothy J Ladewig; Elad Maor; David R Holmes; Suraj Kapa; Samuel J Asirvatham Journal: J Am Heart Assoc Date: 2018-07-09 Impact factor: 5.501
Authors: Marijn H A Groen; Vincent J H M van Driel; Kars Neven; Harry van Wessel; Jacques M T de Bakker; Pieter A F Doevendans; Fred H M Wittkampf; Peter Loh; René van Es Journal: Circ Arrhythm Electrophysiol Date: 2022-08-02
Authors: Alan Sugrue; Vaibhav R Vaidya; Christopher Livia; Deepak Padmanabhan; Anas Abudan; Ameesh Isath; Tyra Witt; Christopher V DeSimone; Paul Stalboerger; Suraj Kapa; Samuel J Asirvatham; Christopher J McLeod Journal: PLoS One Date: 2020-02-21 Impact factor: 3.240