| Literature DB >> 20652548 |
Guannan Wang1, Yuan Gao, Hui Huang, Xingguang Su.
Abstract
A new detection format for multiplexed analysis based on fluorescent encoded magnetic composite nanoparticles is presented. Two kinds of virus were analyzed by this new method: equine influenza virus (EIV) and equine infectious anemia virus (EIAV). Firstly, EIV antigen and EIAV antigen were conjugated to two kinds of fluorescent encoded magnetic composite nanoparticles, while the green-emitting CdTe quantum dots (QDs) were attached to the antibody of EIV and EIAV. Then both green-emitting CdTe QD-labeled antibodies and antigens labeled with fluorescent encoded magnetic composite nanoparticles were used to form an immunoassay system for the detection of EIV and EIAV antigens. The method is time-saving and has higher sensitivity (1.3 ng mL(-1) for EIV antigens and 1.2 ng mL(-1) for EIAV antigens) than the conventional methods. A competitive immunoassay method based on this analysis system was used to detect EIV and EIAV antigens in spiked serum samples with satisfactory results.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20652548 DOI: 10.1007/s00216-010-4001-4
Source DB: PubMed Journal: Anal Bioanal Chem ISSN: 1618-2642 Impact factor: 4.142