Literature DB >> 20652543

Inkjet-printed paperfluidic immuno-chemical sensing device.

Koji Abe1, Kaori Kotera, Koji Suzuki, Daniel Citterio.   

Abstract

This paper reports on an inkjet printing method for the fabrication of lateral flow immunochromatographic devices made from a single piece of filter paper by patterning microfluidic channels and dispensing immunosensing inks, requiring only a single printing apparatus. This "paperfluidic" immunosensing device allows for a less time-consuming and more low-cost fabrication compared with the conventional immunochromatographic strips requiring multiple pads, plastic or nylon backing, and a plastic case. A sandwich immunoreaction was performed on the patterned immunosensing paper device, and the sensitivity of the device was optimized with an IgG model analyte. Inkjet-printed antibodies on the test line and the control line were immobilized by physical adsorption, resulting in a very simple fabrication method applicable for pure cellulose surfaces. The color intensity in the test line and the control line was determined both by naked eye and by means of a color scanner in combination with a simple computer program. With the resulting paperfluidic immunosensing device, human IgG concentrations at least down to 10 μg/l could be detected within 20 min. Additionally, in order to demonstrate the feasibility of a total multianalyte sensing system, a combined immuno-chemical sensing device was also fabricated by patterning an additional microfluidic channel for a chemical assay onto the same paper substrate. This low-cost multianalyte paperfluidic sensing device thus demonstrates the feasibility of simple, portable, and disposable tools for pathogen detection in the field of medical, environmental, and food analyses, possibly resulting in useful devices in remote settings and less-industrialized countries.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20652543     DOI: 10.1007/s00216-010-4011-2

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  34 in total

1.  Perspective on diagnostics for global health.

Authors:  Elain Fu; Paul Yager; Pierre N Floriano; Nicolaos Christodoulides; John T McDevitt
Journal:  IEEE Pulse       Date:  2011-11       Impact factor: 0.924

2.  A perspective on paper-based microfluidics: Current status and future trends.

Authors:  Xu Li; David R Ballerini; Wei Shen
Journal:  Biomicrofluidics       Date:  2012-03-02       Impact factor: 2.800

3.  Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection.

Authors:  Elain Fu; Tinny Liang; Paolo Spicar-Mihalic; Jared Houghtaling; Sujatha Ramachandran; Paul Yager
Journal:  Anal Chem       Date:  2012-04-26       Impact factor: 6.986

Review 4.  Paper-based analytical devices for point-of-care infectious disease testing.

Authors:  C Rozand
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2013-08-25       Impact factor: 3.267

5.  Multiplexed paper analytical device for quantification of metals using distance-based detection.

Authors:  David M Cate; Scott D Noblitt; John Volckens; Charles S Henry
Journal:  Lab Chip       Date:  2015-05-26       Impact factor: 6.799

Review 6.  Toward integrated molecular diagnostic system (i MDx): principles and applications.

Authors:  Seung-Min Park; Andrew F Sabour; Jun Ho Son; Sang Hun Lee; Luke P Lee
Journal:  IEEE Trans Biomed Eng       Date:  2014-05       Impact factor: 4.538

7.  A simple paper-based sensor fabricated by selective wet etching of silanized filter paper using a paper mask.

Authors:  Longfei Cai; Chunxiu Xu; ShuoHong Lin; Jiating Luo; Meidie Wu; Fan Yang
Journal:  Biomicrofluidics       Date:  2014-10-13       Impact factor: 2.800

8.  Determination of nitrite in saliva using microfluidic paper-based analytical devices.

Authors:  Samir A Bhakta; Rubiane Borba; Mario Taba; Carlos D Garcia; Emanuel Carrilho
Journal:  Anal Chim Acta       Date:  2013-11-28       Impact factor: 6.558

Review 9.  Biomedical imaging and sensing using flatbed scanners.

Authors:  Zoltán Göröcs; Aydogan Ozcan
Journal:  Lab Chip       Date:  2014-09-07       Impact factor: 6.799

10.  Controlled release of dry reagents in porous media for tunable temporal and spatial distribution upon rehydration.

Authors:  Gina E Fridley; Huy Q Le; Elain Fu; Paul Yager
Journal:  Lab Chip       Date:  2012-11-07       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.