Literature DB >> 20650665

Comparison of gadofosveset trisodium and gadobenate dimeglumine during time-resolved thoracic MR angiography at 3T.

Alex Frydrychowicz1, Maximilian F Russe, Jelena Bock, Aurélien F Stalder, Thorsten A Bley, Andreas Harloff, Michael Markl.   

Abstract

RATIONALE AND
OBJECTIVES: Gadofosveset trisodium is a blood-pool contrast agent (BPA) that shows a less pronounced r1 relaxivity advantage over gadobenate dimeglumine at 3T than at 1.5T. However, there are few data on image quality during first-pass imaging of the thoracic vasculature with gadofosveset trisodium at 3 T. Therefore, it was the aim of this study to compare first-pass imaging characteristics of gadofosveset trisodium to gadobenate dimeglumine during time-resolved contrast-enhanced three-dimensional magnetic resonance angiography (CE MRA) at 3 T.
MATERIALS AND METHODS: Twenty volunteers underwent time-resolved CE MRA on a 3 T magnetic resonance (MR) system with a standard eight-channel phased-array surface coil, receiving either gadofosveset trisodium (blood pool agent [BPA], n = 10) or gadobenate dimeglumine (standard contrast agent, [SCA], n = 10). Image quality was assessed by two independent readers using a Likert scale ranging from 0 = poor quality to 3 = excellent quality, and relative signal-to-noise and contrast-to-noise ratios were calculated.
RESULTS: Equally good to excellent first-pass image quality was confirmed for time-resolved CE MRA using BPA and SCA (arteries, 2.8 ± 0.2 and 2.6 ± 0.4; veins, 2.5 ± 0.3 and 2.2 ± 0.4; artifacts, 2.4 ± 0.2 and 2.3 ± 0.1). Signal-to-noise and contrast-to-noise ratios showed nonsignificant differences, except for left subclavian artery values. There was an overall nonsignificant superiority in signal-to-noise and contrast-to-noise ratios for standard contrast agent in arterial values and BPA regarding venous values.
CONCLUSIONS: Despite a markedly decreased r1/r2 relaxivity ratio, first-pass imaging characteristics of gadofosveset trisodium and gadobenate dimeglumine are equally well suited for first pass time-resolved CE MRA at 3 T.
Copyright © 2010 AUR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20650665     DOI: 10.1016/j.acra.2010.05.022

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  10 in total

1.  Improved quality and diagnostic confidence achieved by use of dose-reduced gadolinium blood-pool agents for time-resolved intracranial MR angiography.

Authors:  S Dehkharghani; J Kang; A M Saindane
Journal:  AJNR Am J Neuroradiol       Date:  2013-08-22       Impact factor: 3.825

2.  Creating three dimensional models of the right ventricular outflow tract: influence of contrast, sequence, operator, and threshold.

Authors:  Barbara E U Burkhardt; Nicholas K Brown; Jaclyn E Carberry; Marí Nieves Velasco Forte; Nicholas Byrne; Gerald Greil; Tarique Hussain; Animesh Tandon
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-15       Impact factor: 2.357

Review 3.  Blood pool contrast agents for venous magnetic resonance imaging.

Authors:  Irai S Oliveira; Sandeep S Hedgire; Weier Li; Suvranu Ganguli; Anand M Prabhakar
Journal:  Cardiovasc Diagn Ther       Date:  2016-12

4.  Altered aortic shape in bicuspid aortic valve relatives influences blood flow patterns.

Authors:  Susanne Schnell; Danielle A Smith; Alex J Barker; Pegah Entezari; Amir R Honarmand; Maria L Carr; S Chris Malaisrie; Patrick M McCarthy; Jeremy Collins; James C Carr; Michael Markl
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2016-07-26       Impact factor: 6.875

5.  Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula.

Authors:  Jinhee Jang; Peter Schmitt; Bom-yi Kim; Hyun Seok Choi; So-Lyung Jung; Kook-Jin Ahn; Inseong Kim; Munyoung Paek; Bum-soo Kim
Journal:  Neuroradiology       Date:  2014-02-14       Impact factor: 2.804

6.  3.0-T whole-heart coronary magnetic resonance angiography: comparison of gadobenate dimeglumine and gadofosveset trisodium.

Authors:  Fabio S Raman; Marcelo S Nacif; George Cater; Neville Gai; Jacquin Jones; Debiao Li; Christopher T Sibley; Songtao Liu; David A Bluemke
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-21       Impact factor: 2.357

7.  A comparison between gadofosveset trisodium and gadobenate dimeglumine for steady state MRA of the thoracic vasculature.

Authors:  G Paul Camren; Gregory J Wilson; Vikram R Bamra; Khahn Q Nguyen; Daniel S Hippe; Jeffrey H Maki
Journal:  Biomed Res Int       Date:  2014-06-29       Impact factor: 3.411

8.  Mapping of autogenous saphenous veins as an imaging adjunct to peripheral MR angiography in patients with peripheral arterial occlusive disease and peripheral bypass grafting: prospective comparison with ultrasound and intraoperative findings.

Authors:  Ann-Marie Bintu Munda Jah-Kabba; Guido Matthias Kukuk; Dariusch Reza Hadizadeh; Frank Träber; Arne Koscielny; Mustapha Sundifu Kabba; Frauke Verrel; Hans Heinz Schild; Winfried Albert Willinek
Journal:  PLoS One       Date:  2014-11-18       Impact factor: 3.240

9.  A non-invasive magnetic resonance imaging approach for assessment of real-time microcirculation dynamics.

Authors:  Tameshwar Ganesh; Marvin Estrada; Herman Yeger; James Duffin; Hai-Ling Margaret Cheng
Journal:  Sci Rep       Date:  2017-08-07       Impact factor: 4.379

10.  Part 2 - Coronary angiography with gadofosveset trisodium: a prospective intra-subject comparison for dose optimization for 100 % efficiency imaging.

Authors:  Mark A Ahlman; Fabio S Raman; Jianing Pang; Filip Zemrak; Veit Sandfort; Scott R Penzak; Zhaoyang Fan; Songtao Liu; Debiao Li; David A Bluemke
Journal:  BMC Cardiovasc Disord       Date:  2016-03-22       Impact factor: 2.298

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.