Literature DB >> 20648682

Simultaneous acquisition of gradient echo/spin echo BOLD and perfusion with a separate labeling coil.

C B Glielmi1, Q Xu, R C Craddock, X Hu.   

Abstract

Arterial spin labeling-based cerebral blood flow imaging complements blood oxygenation level dependent (BOLD) imaging with a measure that is more quantitative and has better specificity to neuronal activation. Relative to gradient echo BOLD, spin echo BOLD has better spatial specificity because it is less biased to large draining veins. Although there have been many studies comparing simultaneously acquired cerebral blood flow data with gradient echo BOLD data in fMRI, there have been few studies comparing cerebral blood flow with SE BOLD and no study comparing all three. We present a pulse sequence that simultaneously acquires cerebral blood flow data with a separate labeling coil, gradient echo BOLD, and spin echo BOLD images. Simultaneous acquisition avoids interscan variability, allowing more direct assessment and comparison of each contrast's relative specificity and reproducibility. Furthermore, it facilitates studies that may benefit from multiple complementary measures.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20648682      PMCID: PMC2978273          DOI: 10.1002/mrm.22554

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Simultaneous detection of changes in perfusion and BOLD contrast.

Authors:  C Schwarzbauer
Journal:  NMR Biomed       Date:  2000-01       Impact factor: 4.044

2.  Simultaneous perfusion and BOLD imaging using reverse spiral scanning at 3T: characterization of functional contrast and susceptibility artifacts.

Authors:  Yihong Yang; Hong Gu; Wang Zhan; Su Xu; David A Silbersweig; Emily Stern
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

3.  Sustained poststimulus elevation in cerebral oxygen utilization after vascular recovery.

Authors:  Hanzhang Lu; Xavier Golay; James J Pekar; Peter C M Van Zijl
Journal:  J Cereb Blood Flow Metab       Date:  2004-07       Impact factor: 6.200

4.  Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil.

Authors:  S Lalith Talagala; Frank Q Ye; Patrick J Ledden; Scott Chesnick
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

5.  Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla.

Authors:  Laura M Parkes; Jens V Schwarzbach; Annemieke A Bouts; Roel H R Deckers; Pim Pullens; Christian M Kerskens; David G Norris
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

6.  Reproducibility of BOLD, perfusion, and CMRO2 measurements with calibrated-BOLD fMRI.

Authors:  Oleg Leontiev; Richard B Buxton
Journal:  Neuroimage       Date:  2007-01-05       Impact factor: 6.556

7.  What is the correct value for the brain--blood partition coefficient for water?

Authors:  P Herscovitch; M E Raichle
Journal:  J Cereb Blood Flow Metab       Date:  1985-03       Impact factor: 6.200

8.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model.

Authors:  S Ogawa; R S Menon; D W Tank; S G Kim; H Merkle; J M Ellermann; K Ugurbil
Journal:  Biophys J       Date:  1993-03       Impact factor: 4.033

9.  Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.

Authors:  R R Edelman; B Siewert; D G Darby; V Thangaraj; A C Nobre; M M Mesulam; S Warach
Journal:  Radiology       Date:  1994-08       Impact factor: 11.105

10.  Intrinsic signal changes accompanying sensory stimulation: functional brain mapping with magnetic resonance imaging.

Authors:  S Ogawa; D W Tank; R Menon; J M Ellermann; S G Kim; H Merkle; K Ugurbil
Journal:  Proc Natl Acad Sci U S A       Date:  1992-07-01       Impact factor: 11.205

View more
  2 in total

1.  Optimized simultaneous ASL and BOLD functional imaging of the whole brain.

Authors:  Vincent J Schmithorst; Luis Hernandez-Garcia; Jennifer Vannest; Akila Rajagopal; Greg Lee; Scott K Holland
Journal:  J Magn Reson Imaging       Date:  2013-09-24       Impact factor: 4.813

2.  On the sensitivity of the diffusion MRI signal to brain activity in response to a motor cortex paradigm.

Authors:  Alberto De Luca; Lara Schlaffke; Jeroen C W Siero; Martijn Froeling; Alexander Leemans
Journal:  Hum Brain Mapp       Date:  2019-08-13       Impact factor: 5.038

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.