Biocompatibility and mechanical properties of diamond-like coatings on cobalt-chromium-molybdenum steel and titanium-aluminum-vanadium biomedical alloys.

C Hinüber1, C Kleemann, R J Friederichs, L Haubold, H J Scheibe, T Schuelke, C Boehlert, M J Baumann.   

Abstract

Diamond-like carbon (DLC) films are favored for wear components because of diamond-like hardness, low friction, low wear, and high corrosion resistance (Schultz et al., Mat-wiss u Werkstofftech 2004;35:924-928; Lappalainen et al., J Biomed Mater Res B Appl Biomater 2003;66B:410-413; Tiainen, Diam Relat Mater 2001;10:153-160). Several studies have demonstrated their inertness, nontoxicity, and the biocompatibility, which has led to interest among manufacturers of surgical implants (Allen et al., J Biomed Mater Res B Appl Biomater 2001;58:319-328; Uzumaki et al., Diam Relat Mater 2006;15:982-988; Hauert, Diam Relat Mater 2003;12:583-589; Grill, Diam Relat Mater 2003;12:166-170). In this study, hydrogen-free amorphous, tetrahedrally bonded DLC films (ta-C) were deposited at low temperatures by physical vapor deposition on medical grade Co28Cr6Mo steel and the titanium alloy Ti6Al4V (Scheibe et al., Surf Coat Tech 1996;85:209-214). The mechanical performance of the ta-C was characterized by measuring its surface roughness, contact angle, adhesion, and wear behavior, whereas the biocompatibility was assessed by osteoblast (OB) attachment and cell viability via Live/Dead assay. There was no statistical difference found in the wettability as measured by contact angle measurements for the ta-C coated and the uncoated samples of either Co28Cr6Mo or Ti6Al4V. Rockwell C indentation and dynamic scratch testing on 2-10 μm thick ta-C films on Co28Cr6Mo substrates showed excellent adhesion with HF1 grade and up to 48 N for the critical load L(C2) during scratch testing. The ta-C coating reduced the wear from 3.5 × 10(-5) mm(3)/Nm for an uncoated control sample (uncoated Co28Cr6Mo against uncoated stainless steel) to 1.1 × 10(-7) mm(3)/Nm (coated Co28Cr6Mo against uncoated stainless steel) in reciprocating pin-on-disk testing. The lowest wear factor of 3.9 × 10(-10) mm(3)/Nm was measured using a ta-C coated steel ball running against a ta-C coated and polished Co28Cr6Mo disk. Student's t-test found that the ta-C coating had no statistically significant (p < 0.05) effect on OB attachment, when compared with the uncoated control samples. There was no significant difference (p < 0.05) in the Live/Dead assay results in cell death between the ta-C coated Co28Cr6Mo and Ti6Al4V samples and the uncoated controls. Therefore, these ta-C coatings show improved wear and corrosion (Dorner-Reisel et al., Diam Relat Mater 2003;11:823-827; Affato et al., J Biomed Mater Res B Appl Biomater 2000;53:221-226; Dorner-Reisel et al., Surf Coat Tech 2004;177-178:830-837; Kim et al., Diam Relat Mater 2004;14:35-41) performance and excellent in vitro cyto-compatibility, when compared with currently used uncoated Co28Cr6Mo and Ti6Al4V implant materials.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20648536     DOI: 10.1002/jbm.a.32851

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  5 in total

1.  Adhesion and differentiation of Saos-2 osteoblast-like cells on chromium-doped diamond-like carbon coatings.

Authors:  Elena Filova; Marta Vandrovcova; Miroslav Jelinek; Josef Zemek; Jana Houdkova; Tomas Kocourek; Lubica Stankova; Lucie Bacakova
Journal:  J Mater Sci Mater Med       Date:  2016-12-20       Impact factor: 3.896

2.  Biocidal activity of metalloacid-coated surfaces against multidrug-resistant microorganisms.

Authors:  Nathalie Tétault; Houssein Gbaguidi-Haore; Xavier Bertrand; Roland Quentin; Nathalie van der Mee-Marquet
Journal:  Antimicrob Resist Infect Control       Date:  2012-11-14       Impact factor: 4.887

Review 3.  Titanium-Based Hip Stems with Drug Delivery Functionality through Additive Manufacturing.

Authors:  Martin B Bezuidenhout; Dimitar M Dimitrov; Anton D van Staden; Gert A Oosthuizen; Leon M T Dicks
Journal:  Biomed Res Int       Date:  2015-10-04       Impact factor: 3.411

4.  Antibacterial potency of different deposition methods of silver and copper containing diamond-like carbon coated polyethylene.

Authors:  Norbert Harrasser; Sebastian Jüssen; Andreas Obermeir; Ralf Kmeth; Bernd Stritzker; Hans Gollwitzer; Rainer Burgkart
Journal:  Biomater Res       Date:  2016-07-06

5.  CoCrMo surface modifications affect biocompatibility, adhesion, and inflammation in human osteoblasts.

Authors:  Birgit Lohberger; Nicole Stuendl; Dietmar Glaenzer; Beate Rinner; Nicholas Donohue; Helga C Lichtenegger; Leon Ploszczanski; Andreas Leithner
Journal:  Sci Rep       Date:  2020-02-03       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.