[Computer-assisted versus traditional Cobb angle measurement on digital radiograph in scoliosis].

Chu Wang1, Li-feng Lao, Wen-xin Niu, Ze-jun Xing, Gui-xing Qiu, Zhi-hong Wu.   

Abstract

OBJECTIVE: To assess Mimics as a new measurement method in Cobb angle in a comparison with traditional measurement and try to explore the advantages and disadvantages of the new method.
METHODS: Twenty X-ray plates of scoliosis were chosen randomly. Two experienced physicians measured the Cobb angles via Mimics and traditional methods twice with an interval of 1 week. And statistical analyses of Cobb angle and difference between two measurements were carried out.
RESULTS: The overall correlation was 0.986 for Mimics and traditional measurements. ANOVA demonstrated no significant difference between these two methods. A significant difference existed between the first and second values of Cobb angle in Mimics and traditional measurements. However the absolute difference was small.
CONCLUSION: Mimics can be a new method for measuring the digital radiographs. And its precision is superior to that of the traditional measurement.

Entities:  

Mesh:

Year:  2010        PMID: 20646575

Source DB:  PubMed          Journal:  Zhonghua Yi Xue Za Zhi        ISSN: 0376-2491


  2 in total

1.  Factors affecting operating time in laparoscopic anterior resection of rectal cancer.

Authors:  Chu Wang; Yi Xiao; Huizhong Qiu; Jie Yao; Weidong Pan
Journal:  World J Surg Oncol       Date:  2014-02-25       Impact factor: 2.754

2.  Measurement of scoliosis Cobb angle by end vertebra tilt angle method.

Authors:  Jing Wang; Jin Zhang; Rui Xu; Tie Ge Chen; Kai Sheng Zhou; Hai Hong Zhang
Journal:  J Orthop Surg Res       Date:  2018-09-04       Impact factor: 2.359

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.