[The diagnostic value of anti-SSA antibody in primary Sjögren's syndrome].

Meng-tao Li1, Yan Zhao, Wen-jie Zheng, Jin-mei Su, Qing-jun Wu, Ying Jiang, Dong Xu, Wen Zhang, Feng-chun Zhang, Yi Dong.   

Abstract

OBJECTIVE: According to international classification criteria (2002) on Sjögren's syndrome, labial pathology was still considered as a major criterion for diagnosis. Standard labial biopsy was hard to be carried out in China. This study is to evaluate whether the invasive labial biopsy could be replaced by noninvasive detection of serum anti-SSA antibody.
METHODS: 181 Chinese patients with the initial diagnosis of primary Sjögren's syndrome in Peking Union Medical College Hospital (PUMCH) were enrolled in Sjögren's International Collaborative Clinical Alliance (SICCA). All patients received standard labial biopsies (area of salivary gland tissue ≥ 4 mm²) and focal score (FS) of focal lymphatic sialadenitis were confirmed by pathologists from school of stomatology, University California of San Francisco (UCSF). Anti-SSA antibodies in sera of all patients were detected by double immunodiffusion (DID), Western blot in PUMCH and by enzyme-linked immunosorbent assay (ELISA) in central laboratory of SICCA. The correlation between labial pathological findings and serum anti-SSA antibody was studied by chi² test and the concordance was calculated by unweighted Kappa.
RESULTS: (1) Bivariate analysis revealed strong associations of FS > 1 with the presence of anti-SSA antibody by DID (83.9% vs 42.0%, P < 0.0001). The accordance between FS and antibody detection by DID was fine with a kappa value of 0.432. However, there were 16.1% false-positive antibody reports and 42.0% false-negative antibody reports. (2) FS > 1 was strongly associated with the presence of anti-SSA antibody by Western blot (83.0% vs 51.7%, P < 0.0001). But the accordance between FS and antibody detection by Western blot was only fair with a kappa value of 0.316. There were 17.0% false-positive antibody reports and 51.7% false-negative antibody reports. (3) FS > 1 was strongly associated with the presence of anti-SSA antibody by ELISA (81.5% vs 38.6%, P < 0.0001). The accordance between FS and antibody detection by ELISA was fine with a kappa value of 0.427. There were 18.5% false-positive antibody reports and 38.6% false-negative antibody reports.
CONCLUSION: In Sjögren's syndrome, labial biopsy with FS > 1 finding is strongly associated with anti-SSA antibody. Positive results of anti-SSA antibodies by DID or ELISA may indicate FS > 1, thus labial biopsy could relatively be avoided, negative results may need further standard labial biopsy procedure to confirm the diagnosis of Sjögren's syndrome.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20646416

Source DB:  PubMed          Journal:  Zhonghua Nei Ke Za Zhi        ISSN: 0578-1426


  2 in total

1.  Discordant Predictions of Extraglandular Involvement in Primary Sjögren's Syndrome According to the Anti-SSA/Ro60 Antibodies Detection Assay in a Cohort Study.

Authors:  Geoffrey Urbanski; Aline Gury; Pascale Jeannin; Alain Chevailler; Pierre Lozac'h; Pascal Reynier; Christian Lavigne; Carole Lacout; Emeline Vinatier
Journal:  J Clin Med       Date:  2022-01-04       Impact factor: 4.241

2.  Current state of technologies and recognition of anti-SSA/Ro antibodies in China: A multi-center study.

Authors:  Yu-Lan Chen; Chao-Jun Hu; Lin-Yi Peng; Chu-Han Wang; Yan Zhao; Wen Zhang; Dong-Zhou Liu
Journal:  J Clin Lab Anal       Date:  2021-10-21       Impact factor: 2.352

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.