Literature DB >> 20643251

Comparison of automated oscillometric versus auscultatory blood pressure measurement.

Johanna Landgraf1, Stanley H Wishner, Robert A Kloner.   

Abstract

Most clinical offices rely on automated oscillometric devices to measure blood pressure (BP), but the accuracy of this technique versus auscultatory determination using a mercury manometer is controversial. To assess the accuracy of automated oscillometric readings, BP was measured from the same site and cuff, in 337 consecutive patients seen in a routine cardiology office, using a simultaneous connection to an automated oscillometric and a mercury manometer technique. The mean systolic BP (133 +/- 20 mm Hg) and diastolic BP (72 +/- 11 mm Hg) were significantly greater using the mercury manometer than the automated oscillometric technique (systolic 131 +/- 18 and diastolic 70 +/- 12 mm Hg, p <0.0001). Discrepancies (almost always lower oscillometric and greater mercury manometer) in systolic BP were seen in 22% of all patients. Discrepancies in diastolic BP were seen in 20% of all patients. The mean of the discrepancy between the 2 techniques was 1.95 +/- 5 mm Hg (range 1 to 26) for systolic BP and 1.3 +/- 4 mm Hg (range 1 to 25) for diastolic BP. The discrepancies were greater in patients >65 years. In conclusion, the mercury manometer technique resulted in consistently greater BP values than oscillometric devices. These findings have important clinical implications, including the concept that patients whose BP appears to be under control using the oscillometric technique might not be at their goal BP and might have been undertreated. Copyright (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20643251     DOI: 10.1016/j.amjcard.2010.03.040

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  16 in total

Review 1.  KDOQI US Commentary on the 2017 ACC/AHA Hypertension Guideline.

Authors:  Holly J Kramer; Raymond R Townsend; Karen Griffin; Joseph T Flynn; Daniel E Weiner; Michael V Rocco; Michael J Choi; Matthew R Weir; Tara I Chang; Rajiv Agarwal; Srinivasan Beddhu
Journal:  Am J Kidney Dis       Date:  2019-04       Impact factor: 8.860

2.  Effectiveness of in-office blood pressure measurement by eye care practitioners in early detection and management of hypertension.

Authors:  Saud A AlAnazi; Uchechukwu L Osuagwu; Turki M AlMubrad; Hany K Ahmed; Kelechi C Ogbuehi
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

3.  The importance of pulse pressure on cardiovascular risk and total mortality in the general population: Is sex relevant?

Authors:  Marijana Tadic; Fosca Quarti-Trevano; Michele Bombelli; Rita Facchetti; Cesare Cuspidi; Giuseppe Mancia; Guido Grassi
Journal:  J Clin Hypertens (Greenwich)       Date:  2018-04-27       Impact factor: 3.738

4.  Assessing the accuracy of the OMRON HEM-907XL oscillometric blood pressure measurement device in patients with nondialytic chronic kidney disease.

Authors:  Jordana B Cohen; Tiffany C Wong; Bruce S Alpert; Raymond R Townsend
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-01-12       Impact factor: 3.738

5.  Improved Measurement of Blood Pressure by Extraction of Characteristic Features from the Cuff Oscillometric Waveform.

Authors:  Pooi Khoon Lim; Siew-Cheok Ng; Wissam A Jassim; Stephen J Redmond; Mohammad Zilany; Alberto Avolio; Einly Lim; Maw Pin Tan; Nigel H Lovell
Journal:  Sensors (Basel)       Date:  2015-06-16       Impact factor: 3.576

6.  High blood pressure in overweight and obese youth: implications for screening.

Authors:  Corinna Koebnick; Mary Helen Black; Jun Wu; Mayra P Martinez; Ning Smith; Beatriz Kuizon; David Cuan; Deborah Rohm Young; Jean M Lawrence; Steven J Jacobsen
Journal:  J Clin Hypertens (Greenwich)       Date:  2013-10-10       Impact factor: 3.738

7.  Effect of peripheral edema on oscillometric blood pressure measurement.

Authors:  Shamsi Ghaffari; Majid Malaki; Afshin Rezaeifar; Shahin Abdollahi Fakhim
Journal:  J Cardiovasc Thorac Res       Date:  2014-12-30

8.  Current utility of the ankle-brachial index (ABI) in general practice: implications for its use in cardiovascular disease screening.

Authors:  Jane H Davies; Joyce Kenkre; E Mark Williams
Journal:  BMC Fam Pract       Date:  2014-04-17       Impact factor: 2.497

9.  A new automatic blood pressure kit auscultates for accurate reading with a smartphone: A diagnostic accuracy study.

Authors:  Hongjun Wu; Bingjian Wang; Xinpu Zhu; Guang Chu; Zhi Zhang
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

10.  The prevalence of primary pediatric prehypertension and hypertension in a real-world managed care system.

Authors:  Corinna Koebnick; Mary H Black; Jun Wu; Mayra P Martinez; Ning Smith; Beatriz D Kuizon; Steven J Jacobsen; Kristi Reynolds
Journal:  J Clin Hypertens (Greenwich)       Date:  2013-08-07       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.