| Literature DB >> 20642931 |
Roop Singh1, Rajesh Kumar Rohillai, Ramchander Siwach, Zile Singh, Narender Kumar Magu, Sukhbir Singh Sangwan.
Abstract
The authors report a rare per-operative complication of intra-pelvic migration of dynamic hip screw, during osteosynthesis of an inter-trochanteric fracture. Possible reasons of migration are analyzed along with the importance of careful execution of the surgical technique to avoid such iatrogenic complications and medico-legal implications.Entities:
Mesh:
Year: 2010 PMID: 20642931 DOI: 05.2010/JCPSP.341342
Source DB: PubMed Journal: J Coll Physicians Surg Pak ISSN: 1022-386X Impact factor: 0.711