Rapid identification and semi-quantitative determination of polymer additives by desorption electrospray ionization/time-of-flight mass spectrometry.

Silke M Reiter1, Wolfgang Buchberger, Christian W Klampfl.   

Abstract

A fast and simple method for the direct qualitative and semi-quantitative determination of a set of four polymer additives in plastic samples by desorption electrospray ionization time-of-flight mass spectrometry (DESI-TOF-MS) is presented. After evaluation of crucial DESI parameters such as composition of spray solutions and spray voltages, a series of lab-made polypropylene samples containing Chimassorb 81 (2-hydroxy-4-n-octoxybenzophenone), Tinuvin 328 (2-(2-hydroxy-3, 5-ditert-pentylphenyl)-benzotriazole), Tinuvin 326 (2-(2-hydroxy-3-tert-butyl-5-methylphenyl)-5-chloro benzotriazole), and Tinuvin 770 (bis(2,2,6,6,-tetramethyl-4-piperidyl)sebaceate) in concentrations between 0.02% and 0.2% were analyzed, resulting in calibration graphs with R (2) better than 0.994. To demonstrate the applicability of the developed method for the investigation of real samples, liners for in-ground swimming pools and polypropylene granules were analyzed with respect to their content in the selected polymer additives. Two alternative methods, both well established in the fields of polymer additive analysis, namely HPLC with UV detection (after previous extraction) and thermodesorption gas chromatography/mass spectrometry have been employed for evaluation of the results from the DESI experiments.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20640407     DOI: 10.1007/s00216-010-3989-9

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Quantitative analysis of polymer additives with MALDI-TOF MS using an internal standard approach.

Authors:  Clemens Schwarzinger; Stefan Gabriel; Susanne Beißmann; Wolfgang Buchberger
Journal:  J Am Soc Mass Spectrom       Date:  2012-03-27       Impact factor: 3.109

2.  Sensitivity "hot spots" in the direct analysis in real time mass spectrometry of nerve agent simulants.

Authors:  Glenn A Harris; Caitlin E Falcone; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2011-11-02       Impact factor: 3.109

3.  The quantitative surface analysis of an antioxidant additive in a lubricant oil matrix by desorption electrospray ionization mass spectrometry.

Authors:  Caitlyn Da Costa; James C Reynolds; Samuel Whitmarsh; Tom Lynch; Colin S Creaser
Journal:  Rapid Commun Mass Spectrom       Date:  2013-11-15       Impact factor: 2.419