Literature DB >> 20640361

Radiographic analysis of root canal fillings: influence of two sealers on the perception of voids.

Augusto Bodanezi1, Etiene de Andrade Munhoz, Norberti Bernardineli, Ana Lúcia Alvares Capelozza, Ivaldo Gomes de Moraes, Clovis Monteiro Bramante.   

Abstract

The aim of this ex vivo was to investigate if two radiopaque root canal sealers with different formulations would influence the radiographic perception of root canal fillings. The root canals of 48 extracted maxillary canines were prepared and randomly assigned to 3 groups of 16 specimens each. In each group, the root canals were filled by lateral condensation of gutta-percha and one of the tested sealers: Endométhasone, Sealer 26, or a non-radiopaque sealer. A through-and-through void was simulated in half of the specimens from each group (n=8). The buccolingual radiographic images obtained were randomly interpreted for voids existence by a radiologist and an endodontist. The differences in sensitivity and specificity between groups and examiners were compared using, respectively, Fisher's Exact and McNemar tests at 5% significance level. Both radiopaque sealers caused a significant decrease in sensitivity at the coronal part of fillings. The use of Endométhasone increased specificity values for both coronal and apical portions of the root canal fillings. In conclusion, the tested sealers influenced the radiographic perceptions of laterally condensed root canal fillings in a different way.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20640361     DOI: 10.1590/s0103-64402010000200009

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  5 in total

1.  Interference of partial visual analysis of root filling quality and apical status on retreatment decisions.

Authors:  Renata Dornelles Morgental; Régis Burmeister dos Santos; Cassiano Kuchenbecker Rösing; Taís do Amaral Chanin; José Antônio Poli de Figueiredo
Journal:  J Appl Oral Sci       Date:  2012 Mar-Apr       Impact factor: 2.698

2.  The impact of the addition of iodoform on the physicochemical properties of an epoxy-based endodontic sealer.

Authors:  Milton Carlos Kuga; Gisele Faria; Marcus Vinicius Só; Katia Cristina Keine; Alailson Domingos dos Santos; Marco Antonio Hungaro Duarte; Patricia Maria Poli Kopper
Journal:  J Appl Oral Sci       Date:  2014-04       Impact factor: 2.698

3.  Comparison of Obturation Quality in Modified Continuous Wave Compaction, Continuous Wave Compaction, Lateral Compaction and Warm Vertical Compaction Techniques.

Authors:  Mohsen Aminsobhani; Abdollah Ghorbanzadeh; Mohammad Reza Sharifian; Sara Namjou; Mohamad Javad Kharazifard
Journal:  J Dent (Tehran)       Date:  2015-02

4.  Comparative Evaluation of Instrumentation Time, Obturation Time, and Radiographic Quality of Obturation Using Two Rotary Systems and Manual Technique for Primary Molar Pulpectomies - In vivo Study.

Authors:  Heeral Sureshkumar Shah; Vishwas Mohanrao Patil; Ananth P Kamath; Aditi Anmol Mathur
Journal:  Contemp Clin Dent       Date:  2021-03-20

5.  Influence of root canal sealer on the radiographic appearance of filling voids in maxillary single-rooted teeth.

Authors:  Augusto Bodanezi; Etiene Andrade Munhoz; Ana Lúcia Álvares Capelozza; Norberti Bernardineli; Ivaldo Gomes de Moraes; Roberto Brandão Garcia; Clovis Monteiro Bramante
Journal:  J Appl Oral Sci       Date:  2012 Jul-Aug       Impact factor: 2.698

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.