Literature DB >> 20638615

A comparison in proximal tibial strain between metal-backed and all-polyethylene anatomic graduated component total knee arthroplasty tibial components.

Scott R Small1, Michael E Berend, Merrill A Ritter, Christine A Buckley.   

Abstract

Loading in total knee arthroplasty (TKA) is multifactorial and dependent on alignment, ligament balance, patient, and implant factors. Abnormal loading has been linked to clinical failure; however, the respective contribution of each factor to failure is not well known. This study defined the effect of metal backing on loading patterns in the proximal tibia. Composite tibiae were implanted with metal-backed and all-polyethylene Anatomic Graduated Component TKA tibial components (Biomet, Inc, Warsaw, Ind) and coated with photoelastic material allowing full-field dynamic strain quantification. In simulated varus loading distributions, significant increases in measured strain were observed ranging from 40% to 587% for all-polyethylene vs metal-backed tibial components. Higher observed strains in the proximal tibia observed with all-polyethylene tibial components could possibly explain increased clinical failure rates observed with this TKA design. Copyright (c) 2010. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20638615     DOI: 10.1016/j.arth.2009.06.018

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

Review 1.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

2.  Finite element analysis: a comparison of an all-polyethylene tibial implant and its metal-backed equivalent.

Authors:  S M Thompson; D Yohuno; W N Bradley; A D Crocombe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-22       Impact factor: 4.342

3.  Polished trays reduce backside wear independent of post location in posterior-stabilized TKAs.

Authors:  Matthew P Abdel; Mark W Gesell; Christen W Hoedt; Kathleen N Meyers; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2014-04-15       Impact factor: 4.176

4.  Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.

Authors:  Tao Cheng; Guoyou Zhang; Xianlong Zhang
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

  4 in total