Evaluation of short-term response of high intensity focused ultrasound ablation for primary hepatic carcinoma: utility of contrast-enhanced MRI and diffusion-weighted imaging.

Yuanyuan Zhang1, Jiannong Zhao, Dajing Guo, Weijia Zhong, Lifen Ran.   

Abstract

OBJECTIVE: To explore the significance of contrast-enhanced MRI (CE-MRI) and diffusion-weighted imaging (DWI) in evaluating the short-term response of high intensity focused ultrasound (HIFU) ablation for primary hepatic carcinoma (PHC).
METHODS: Thirty-nine lesions in the livers of 27 patients were performed HIFU ablation. Conventional MRI sequences, CE-MRI and DWI were performed 1 week before HIFU and 1 week, 3 months after the therapy, respectively. The short-term responses of HIFU for all lesions were evaluated with MRI.
RESULTS: 28 of the 39 lesions (28/39, 71.8%) showed complete necrosis with no enhancement 1 week and 3 months after HIFU. The apparent diffusion coefficient (ADC) values 1 week and 3 months after HIFU were significantly higher than those 1 week before treatment (p<0.05). The tumor recurrence was detected in 7 of the 39 lesions (7/39, 17.9%) which had no significant enhancement 1 week after HIFU. On the 3 months follow-up, focal nodules were found on the inner aspects of the treated areas. The ADC values had no significant difference between 1 week before and after treatment (p>0.05), however, they were significantly higher 3 months after HIFU (p<0.05). The tumor residuals were detected in 4 of the 39 lesions (4/39, 10.3%) showing enhancement 1 week after treatment and increased size 3 months after HIFU. The ADC values had no significant difference among 1 week before HIFU, 1 week and 3 months after treatment (p>0.05).
CONCLUSION: CE-MRI and DWI can be employed to evaluate the short-term response of HIFU ablation for PHC and to guide the patient management.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20638211     DOI: 10.1016/j.ejrad.2010.06.039

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  12 in total

1.  Diffusion-weighted MR imaging in gynecologic cancers.

Authors:  Shigenobu Motoshima; Hiroyuki Irie; Takahiko Nakazono; Toshiharu Kamura; Sho Kudo
Journal:  J Gynecol Oncol       Date:  2011-12-05       Impact factor: 4.401

Review 2.  High intensity focused ultrasound (HIFU) applied to hepato-bilio-pancreatic and the digestive system-current state of the art and future perspectives.

Authors:  Michele Diana; Luigi Schiraldi; Yu-Yin Liu; Riccardo Memeo; Didier Mutter; Patrick Pessaux; Jacques Marescaux
Journal:  Hepatobiliary Surg Nutr       Date:  2016-08       Impact factor: 7.293

Review 3.  Diffusion MRI in early cancer therapeutic response assessment.

Authors:  C J Galbán; B A Hoff; T L Chenevert; B D Ross
Journal:  NMR Biomed       Date:  2016-01-15       Impact factor: 4.044

Review 4.  Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours.

Authors:  J W Wijlemans; L W Bartels; R Deckers; M Ries; W P Th M Mali; C T W Moonen; M A A J van den Bosch
Journal:  Cancer Imaging       Date:  2012-09-28       Impact factor: 3.909

5.  Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases.

Authors:  Mie K Lam; Merel Huisman; Robbert J Nijenhuis; Maurice Aaj van den Bosch; Max A Viergever; Chrit Tw Moonen; Lambertus W Bartels
Journal:  J Ther Ultrasound       Date:  2015-03-24

6.  The Value of Proton Magnetic Resonance Spectroscopy in High-Intensity Focused Ultrasound Treatment of Experimental Liver Cancer.

Authors:  Zhuo-Yue Tang; Jian-Nong Zhao; Wei-Jia Zhong; Yin-Deng Luo; Wei Wu; Wei-Juan Chen; Yu-Bing Dai
Journal:  Transl Oncol       Date:  2015-06       Impact factor: 4.243

7.  Multiparametric MRI analysis for the identification of high intensity focused ultrasound-treated tumor tissue.

Authors:  Stefanie J C G Hectors; Igor Jacobs; Gustav J Strijkers; Klaas Nicolay
Journal:  PLoS One       Date:  2014-06-13       Impact factor: 3.240

8.  Contrast-enhanced ultrasound evaluation of pancreatic cancer xenografts in nude mice after irradiation with sub-threshold focused ultrasound for tumor ablation.

Authors:  Yi Hui Gao; Lei Wu; Rui Wang; Qian Guo; Yi Ni Chen; Bing Hu; Li Xin Jiang
Journal:  Oncotarget       Date:  2017-06-06

9.  Role of diffusion-weighted imaging in monitoring treatment response following high-intensity focused ultrasound ablation of recurrent sacral chordoma.

Authors:  Madhurima R Chetan; Paul C Lyon; Feng Wu; Rachel Phillips; David Cranston; Martin J Gillies; Stana Bojanic
Journal:  Radiol Case Rep       Date:  2019-08-01

Review 10.  Application of Different Imaging Methods in the Early Diagnosis of Primary Hepatic Carcinoma.

Authors:  Xin'ai Wu; Jianbo Li; Cheng Wang; Guojian Zhang; Na Zheng; Xuemei Wang
Journal:  Gastroenterol Res Pract       Date:  2015-12-24       Impact factor: 2.260

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.