Literature DB >> 20637650

Improved detection of toxic chemicals by Photobacterium phosphoreum using modified Boss medium.

Sedky H A Hassan1, Sang Eun Oh.   

Abstract

A bioluminescent bacterium Photobacterium phosphoreum has been used widely as an indicator of pollutants where the presence of toxic chemicals decreases light output. The optimum conditions for the growth and bioluminescence of P. phosphoreum KCTC 2852 were investigated using modified Boss medium and two environmental conditions (pH and temperature). Optimized conditions that supported growth of P. phosphoreum with high bioluminescence intensities were: NaCl (20 g/L), glycerol (2.5 g/L), peptone (1.0 g/L), and yeast extract (1.0 g/L). Growth and bioluminescence gradually increased as pH increased reaching a maximum at pH 7.0. The maximum temperature for growth and bioluminescence was 20 degrees C. Based on these optimum conditions for bioluminescence, a continuous culture reactor of P. phosphoreum was operated. During the continuous operation, the optimized medium maintained bioluminescence with a high relative light unit (RLU) around 13,600 for more than 120 h. When zinc (0.5 mg/L) was added to the reactor, an EC(50) was observed in 15 min. The detection limit was improved by using the modified Boss medium since the modified Boss medium contained less organic matter which minimizes the complexation and precipitation of heavy metals compared to other enrichment media with high levels of organic matter. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20637650     DOI: 10.1016/j.jphotobiol.2010.06.006

Source DB:  PubMed          Journal:  J Photochem Photobiol B        ISSN: 1011-1344            Impact factor:   6.252


  4 in total

1.  Acute and Chronic Toxicity of Binary Mixtures of Bisphenol A and Heavy Metals.

Authors:  Jun Yang; Anqi Liao; Shulin Hu; Yiwen Zheng; Shuli Liang; Shuangyan Han; Ying Lin
Journal:  Toxics       Date:  2022-05-17

2.  LuxCDABE--transformed constitutively bioluminescent Escherichia coli for toxicity screening: comparison with naturally luminous Vibrio fischeri.

Authors:  Imbi Kurvet; Angela Ivask; Olesja Bondarenko; Mariliis Sihtmäe; Anne Kahru
Journal:  Sensors (Basel)       Date:  2011-08-11       Impact factor: 3.576

3.  An Intact Cell Bioluminescence-Based Assay for the Simple and Rapid Diagnosis of Urinary Tract Infection.

Authors:  Sherwin Reyes; Nga Le; Mary Denneth Fuentes; Jonathan Upegui; Emre Dikici; David Broyles; Edward Quinto; Sylvia Daunert; Sapna K Deo
Journal:  Int J Mol Sci       Date:  2020-07-16       Impact factor: 5.923

4.  Comparison of Microtox and Xenoassay light as a near real time river monitoring assay for heavy metals.

Authors:  M I E Halmi; Hussain Jirangon; W L W Johari; A R Abdul Rachman; M Y Shukor; M A Syed
Journal:  ScientificWorldJournal       Date:  2014-04-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.