BACKGROUND: Anisotropy of the skin varies depending on different locations and pathological conditions. Currently, no reliable non-invasive measurement tool is available for tissue anisotropy. The Reviscometer is an anisotropy measurement tool that measures the resonance running time (RRT) of a shock wave. This study was initiated to establish the reliability of the Reviscometer on normal skin and scars, and to provide basic information on tissue alignment in normal skin and scars.
METHODS: Fifty volunteers and 50 patients underwent measurements on normal skin and scars, respectively. All measurements were performed by the same two observers. Measurements on normal skin were performed on the forearm, upper arm, and abdomen.
RESULTS: The results showed that the intraclass correlation coefficient of the inter-observer reliability was > or =0.79 on normal skin and > or =0.86 on scars. In normal skin, the highest mean RRT was found on the abdomen (156.4+/-48.8), followed by the upper arm (123.2+/-33.6) and the forearm (112.5+/-24.3). A significantly lower mean RRT was found in scars (52.3+/-21.9) compared with normal skin (91.6+/-37.7).
CONCLUSION: Reviscometer measurements were reliable for normal skin and scars. In addition, clear differences between scars and normal skin but also within different locations on normal skin were identified. The Reviscometer can be considered for the evaluation of the efficacy of different treatments.

Entities:  

Mesh:

Year:  2010        PMID: 20637002     DOI: 10.1111/j.1600-0846.2010.00436.x

Source DB:  PubMed          Journal:  Skin Res Technol        ISSN: 0909-752X            Impact factor:   2.365


  4 in total

1.  A quantitative approach to scar analysis.

Authors:  Hooman Khorasani; Zhong Zheng; Calvin Nguyen; Janette Zara; Xinli Zhang; Joyce Wang; Kang Ting; Chia Soo
Journal:  Am J Pathol       Date:  2011-02       Impact factor: 4.307

2.  The reliability of non-invasive biophysical outcome measures for evaluating normal and hyperkeratotic foot skin.

Authors:  Farina Hashmi; Ciaran Wright; Christopher Nester; Sharon Lam
Journal:  J Foot Ankle Res       Date:  2015-07-09       Impact factor: 2.303

3.  Skin collagen fiber molecular order: a pattern of distributional fiber orientation as assessed by optical anisotropy and image analysis.

Authors:  Juliana Fulan Ribeiro; Eli Heber Martins dos Anjos; Maria Luiza S Mello; Benedicto de Campos Vidal
Journal:  PLoS One       Date:  2013-01-18       Impact factor: 3.240

Review 4.  A systematic review of objective burn scar measurements.

Authors:  Kwang Chear Lee; Janine Dretzke; Liam Grover; Ann Logan; Naiem Moiemen
Journal:  Burns Trauma       Date:  2016-04-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.