Literature DB >> 20636422

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identification.

A Bizzini1, G Greub.   

Abstract

Until recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques for the identification of microorganisms remained confined to research laboratories. In the last 2 years, the availability of relatively simple to use MALDI-TOF MS devices, which can be utilized in clinical microbiology laboratories, has changed the laboratory workflows for the identification of pathogens. Recently, the first prospective studies regarding the performance in routine bacterial identification showed that MALDI-TOF MS is a fast, reliable and cost-effective technique that has the potential to replace and/or complement conventional phenotypic identification for most bacterial strains isolated in clinical microbiology laboratories. For routine bacterial isolates, correct identification by MALDI-TOF MS at the species level was obtained in 84.1-93.6% of instances. In one of these studies, a protein extraction step clearly improved the overall valid identification yield, from 70.3% to 93.2%. This review focuses on the current state of use of MALDI-TOF MS for the identification of routine bacterial isolates and on the main difficulties that may lead to erroneous or doubtful identifications.
© 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

Mesh:

Substances:

Year:  2010        PMID: 20636422     DOI: 10.1111/j.1469-0691.2010.03311.x

Source DB:  PubMed          Journal:  Clin Microbiol Infect        ISSN: 1198-743X            Impact factor:   8.067


  122 in total

1.  Species identification of clinical Prevotella isolates by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

Authors:  Ingrid Wybo; Oriane Soetens; Annelies De Bel; Fedoua Echahidi; Ellen Vancutsem; Kristof Vandoorslaer; Denis Piérard
Journal:  J Clin Microbiol       Date:  2012-02-01       Impact factor: 5.948

2.  Detection of OmpK36 porin loss in Klebsiella spp. by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

Authors:  Jia Chang Cai; Yan Yan Hu; Rong Zhang; Hong Wei Zhou; Gong-Xiang Chen
Journal:  J Clin Microbiol       Date:  2012-04-04       Impact factor: 5.948

3.  Comparison of an in-house method and the commercial Sepsityper™ kit for bacterial identification directly from positive blood culture broths by matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry.

Authors:  D Martiny; A Dediste; O Vandenberg
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-02-25       Impact factor: 3.267

4.  Comparison of the Microflex LT and Vitek MS systems for routine identification of bacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

Authors:  Delphine Martiny; Laurent Busson; Ingrid Wybo; Rachid Ait El Haj; Anne Dediste; Olivier Vandenberg
Journal:  J Clin Microbiol       Date:  2012-02-08       Impact factor: 5.948

5.  Matrix-assisted laser desorption ionization-time of flight mass spectrometry analysis of Gram-positive, catalase-negative cocci not belonging to the Streptococcus or Enterococcus genus and benefits of database extension.

Authors:  Jens Jørgen Christensen; Rimtas Dargis; Monja Hammer; Ulrik Stenz Justesen; Xiaohui C Nielsen; Michael Kemp
Journal:  J Clin Microbiol       Date:  2012-03-07       Impact factor: 5.948

6.  Species identification of clinical isolates of anaerobic bacteria: a comparison of two matrix-assisted laser desorption ionization-time of flight mass spectrometry systems.

Authors:  Ulrik Stenz Justesen; Anette Holm; Elisa Knudsen; Line Bisgaard Andersen; Thøger Gorm Jensen; Michael Kemp; Marianne Nielsine Skov; Bente Gahrn-Hansen; Jens Kjølseth Møller
Journal:  J Clin Microbiol       Date:  2011-10-12       Impact factor: 5.948

7.  Direct identification of bacteria from charcoal-containing blood culture bottles using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry.

Authors:  N Wüppenhorst; C Consoir; D Lörch; C Schneider
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-05-26       Impact factor: 3.267

8.  Comparison of Bruker Biotyper matrix-assisted laser desorption ionization-time of flight mass spectrometer to BD Phoenix automated microbiology system for identification of gram-negative bacilli.

Authors:  Ryan T Saffert; Scott A Cunningham; Sherry M Ihde; Kristine E Monson Jobe; Jayawant Mandrekar; Robin Patel
Journal:  J Clin Microbiol       Date:  2011-01-05       Impact factor: 5.948

9.  Does the Capsule Interfere with Performance of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Cryptococcus neoformans and Cryptococcus gattii?

Authors:  Danilo Y Thomaz; Rafaella C Grenfell; Monica S M Vidal; Mauro C Giudice; Gilda M B Del Negro; Luiz Juliano; Gil Benard; João N de Almeida Júnior
Journal:  J Clin Microbiol       Date:  2015-12-09       Impact factor: 5.948

Review 10.  Managing marine mollusc diseases in the context of regional and international commerce: policy issues and emerging concerns.

Authors:  Ryan B Carnegie; Isabelle Arzul; David Bushek
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2016-03-05       Impact factor: 6.237

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.