Abstract

UNLABELLED: Twenty five pairs (50 bones) of cadaveric femora were studied morphologically and radio logically using standardized techniques to obtain anthropometric data to evaluate the applicability of internationally designed implant and to generate a database for proximal femur to help in design for future implant if these were found unsuitable. MEASUREMENTS: femoral head diameter, femoral neck diameter, diameter of proximal femur, canal width at above and below lesser trochanter and 7.5 cm below lower margin of lesser trochanter, endosteal and extracortical width, isthmus position from lesser trochanter, femoral neck anteversion, neck shaft angle and intramedullary axis of femur. The mean +/- SD of these values were calculated. These values were compared with those reported in the literature for Hong Kong Chinese, Caucasians and were found to be different. The implant designed for western population should be used judiciously and facture implant designed should be specific for (ours) bones. We found the pyriformis fossa is usually not in line with the intramedullary axis. Thus antegrade itramedullary nailing portal should be anterior and lateral to pyriformis fossa.

Mesh:

Year:  2009        PMID: 20635610

Source DB:  PubMed          Journal:  Nepal Med Coll J


  6 in total

1.  Estimation of Total Length of Femur from its Proximal and Distal Segmental Measurements of Disarticulated Femur Bones of Nepalese Population using Regression Equation Method.

Authors:  Laxman Khanal; Sandip Shah; Sarun Koirala
Journal:  J Clin Diagn Res       Date:  2017-03-01

2.  Intramedullary Nailing Combined with Bone Grafting for Benign Lesions of the Proximal Femur.

Authors:  Yan Zhang; Jia-Zhen Li; Xin-Chang Lu; Yi Zhang; Huai-Shuan Zhang; Hai-Long Shi; Zheng Lei; Guang Feng; Wei-Ping Fu
Journal:  Orthop Surg       Date:  2017-03-16       Impact factor: 2.071

3.  Design process of cementless femoral stem using a nonlinear three dimensional finite element analysis.

Authors:  Mohd Yusof Baharuddin; Sh-Hussain Salleh; Ahmad Hafiz Zulkifly; Muhammad Hisyam Lee; Alias Mohd Noor; Arief Ruhullah A Harris; Norazman Abdul Majid; Ab Saman Abd Kader
Journal:  BMC Musculoskelet Disord       Date:  2014-02-03       Impact factor: 2.362

4.  Morphological study of the newly designed cementless femoral stem.

Authors:  Mohd Yusof Baharuddin; Sh-Hussain Salleh; Ahmad Hafiz Zulkifly; Muhammad Hisyam Lee; Alias Mohd Noor
Journal:  Biomed Res Int       Date:  2014-06-16       Impact factor: 3.411

5.  The Analysis of Biomechanical Properties of Proximal Femur after Implant Removal.

Authors:  Jae Hyuk Yang; Tae Gon Jung; Arjun Rupanagudi Honnurappa; Jae Min Cha; Chang Hwa Ham; Tae Yoon Kim; Seung Woo Suh
Journal:  Appl Bionics Biomech       Date:  2016-08-11       Impact factor: 1.781

6.  Assessment of the geometry of proximal femur for short cephalomedullary nail placement: An observational study in dry femora and living subjects.

Authors:  Devendra Pathrot; Rehan Ul Haq; Aditya N Aggarwal; Mahindra Nagar; Shuchi Bhatt
Journal:  Indian J Orthop       Date:  2016 May-Jun       Impact factor: 1.251

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.