Literature DB >> 20633845

Real-time 3D fusion echocardiography.

Cezary Szmigielski1, Kashif Rajpoot, Vicente Grau, Saul G Myerson, Cameron Holloway, J Alison Noble, Richard Kerber, Harald Becher.   

Abstract

OBJECTIVES: This study assessed 3-dimensional fusion echocardiography (3DFE), combining several real-time 3-dimensional echocardiography (RT3DE) full volumes from different transducer positions, for improvement in quality and completeness of the reconstructed image.
BACKGROUND: The RT3DE technique has limited image quality and completeness of datasets even with current matrix transducers.
METHODS: RT3DE datasets were acquired in 32 participants (mean age 33.7 +/- 18.8 years; 27 men, 5 women). The 3DFE technique was also performed on a cardiac phantom. The endocardial border definition of RT3DE and 3DFE segments was graded for quality: good (2), intermediate (1), poor (0), or out of sector. Short-axis and apical images were compared in RT3DE and 3DFE, yielding 2,048 segments. The images were processed to generate 3DFE and then compared with cardiac magnetic resonance.
RESULTS: In the heart phantom, fused datasets showed improved contrast to noise ratio from 49.4 +/- 25.1 (single dataset) to 125.4 +/- 25.1 (6 datasets fused together). In subjects, more segments were graded as good quality with 3DFE (805 vs. 435; p < 0.0001) and fewer as intermediate (184 vs. 283; p = 0.017), poor (31 vs. 265; p < 0.0001), or out of sector (4 vs. 41; p < 0.001) compared with the single 3-dimensional dataset. End-diastolic volume (EDV) and end-systolic volume (ESV) obtained from 3-dimensional fused datasets were equivalent to those from single datasets (EDV 118.2 +/- 39 ml vs. 119.7 +/- 43 ml; p = 0.41; ESV 48.1 +/- 30 ml vs. 48.4 +/- 35 ml; p = 0.87; ejection fraction [EF] 61.0 +/- 10% vs. 61.8 +/- 10%; p = 0.44). Bland-Altman analysis showed good 95% limits of agreement for the nonfused datasets (EDV +/-46 ml; ESV +/-36 ml; EF +/-14%) and the fused datasets (EDV +/-45 ml; ESV +/-35 ml; EF +/-16%), when compared with cardiac magnetic resonance.
CONCLUSIONS: Fusion of full-volume datasets resulted in an improvement in endocardial borders, image quality, and completeness of the datasets. Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20633845     DOI: 10.1016/j.jcmg.2010.03.010

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  5 in total

1.  Multiframe registration of real-time three-dimensional echocardiography time series.

Authors:  Harriët W Mulder; Marijn van Stralen; Heleen B van der Zwaan; K Y Esther Leung; Johan G Bosch; Josien P W Pluim
Journal:  J Med Imaging (Bellingham)       Date:  2014-04-23

2.  Ultrasonic image analysis and image-guided interventions.

Authors:  J Alison Noble; Nassir Navab; H Becher
Journal:  Interface Focus       Date:  2011-06-15       Impact factor: 3.906

3.  Three-dimensional echocardiography in a dynamic heart phantom: comparison of five different methods to measure chamber volume using a commercially available software.

Authors:  Peter W Wood; Patrick H Gibson; Harald Becher
Journal:  Echo Res Pract       Date:  2014-10-09

4.  Imaging 4D morphology and dynamics of mitral annulus in humans using cardiac cine MR feature tracking.

Authors:  Shuang Leng; Shuo Zhang; Meng Jiang; Xiaodan Zhao; Rui Wu; John Allen; Ben He; Ru San Tan; Liang Zhong
Journal:  Sci Rep       Date:  2018-01-08       Impact factor: 4.379

5.  Aortic root movement correlation with the function of the left ventricle.

Authors:  Piotr Karwat; Ziemowit Klimonda; Grzegorz Styczyński; Cezary Szmigielski; Jerzy Litniewski
Journal:  Sci Rep       Date:  2021-02-24       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.