Literature DB >> 20632592

Regression error estimation significantly improves the region-of-interest statistics of noisy MR images.

Vladimir Juras1, Stefan Zbýn, Pavol Szomolanyi, Siegfried Trattnig.   

Abstract

PURPOSE: The region-of-interest (ROI) selection and evaluation is one of the key factors in the successful evaluation of radiological images. However, the presence of noise in images may lead to incorrect diagnosis. The aim of this study was to test the hypothesis that the weighting by error estimation in ROI assessment might significantly improve the validity of the results.
METHODS: As a model, the data maps of the transverse relaxation time constants (T2) from patients who underwent a matrix-associated chondrocyte transplantation procedure on the femoral condyle were analyzed. Artificial noise with a Rician density probability distribution was added to each TE image. ROIs were processed either as a regular arithmetic mean or as a weighted mean, in which weighted coefficients were calculated with regard to fitting error estimates [coefficient of determination (R2); root mean squared error (RMSE), mean absolute error (MSE), mean squared error (MAE), and chi-squared error (chi2)].
RESULTS: The global T2 values in repair tissue (mean +/- standard deviation, 62 +/- 7 ms; range 51-70 ms) and in healthy cartilage (mean +/- SD, 49 +/- 6 ms; range 40-60 ms) were significantly different (p < 0.001). With a 45% or greater decrease from the original SNR value (corresponding to a noise level of 35% of random value), the statistical significance was lost (P > 0.05); however, the use of the coefficient of determination (R2) as a correction factor was able to maintain the p-value of < 0.05 up to a 56% decrease from the original SNR value.
CONCLUSIONS: The results of this study can prospectively be applied in a wide range of radiological imaging techniques in cases when error estimation is possible. Our analysis on MR images with artificially added noise showed that utilization of the correlation of determination (R2) as a weighting parameter in ROI evaluation may significantly improve the differentiation between native and transplanted cartilage tissue in noisy images. This could be an added benefit in the non-invasive monitoring of the post-operative status of patients with cartilage transplants if the MR images are not ideal (e.g., lower field strength or lower SNR).

Entities:  

Mesh:

Year:  2010        PMID: 20632592     DOI: 10.1118/1.3431995

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Quantitative bi-component T2* analysis of histologically normal Achilles tendons.

Authors:  Eric Y Chang; Jiang Du; Sheronda Statum; Chantal Pauli; Christine B Chung
Journal:  Muscles Ligaments Tendons J       Date:  2015-07-03

Review 2.  Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping.

Authors:  Rachel K Surowiec; Erin P Lucas; Charles P Ho
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-30       Impact factor: 4.342

3.  Quantitative MRI analysis of menisci using biexponential T2* fitting with a variable echo time sequence.

Authors:  Vladimir Juras; Sebastian Apprich; Štefan Zbýň; Lukas Zak; Xeni Deligianni; Pavol Szomolanyi; Oliver Bieri; Siegfried Trattnig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

4.  Bi-exponential T2 analysis of healthy and diseased Achilles tendons: an in vivo preliminary magnetic resonance study and correlation with clinical score.

Authors:  Vladimir Juras; Sebastian Apprich; Pavol Szomolanyi; Oliver Bieri; Xeni Deligianni; Siegfried Trattnig
Journal:  Eur Radiol       Date:  2013-06-13       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.