Literature DB >> 20631083

Orthodontic forces released by low-friction versus conventional systems during alignment of apically or buccally malposed teeth.

Tiziano Baccetti1, Lorenzo Franchi, Matteo Camporesi, Efisio Defraia.   

Abstract

The aim of the present study was to analyse the forces released by passive stainless steel self-ligating brackets (SLBs) and by a non-conventional elastomeric ligature-bracket system on conventional brackets ([slide ligatures on conventional brackets (SLCB)]) when compared with conventional elastomeric ligatures on conventional brackets (CLCB) during the alignment of apically or buccally malposed teeth in the maxillary arch. An experimental model consisting of five brackets was used to assess the forces released by the three different bracket-ligature systems with 0.012-inch super-elastic (SE) nickel-titanium (NiTi) wires in the presence of different amounts of apical or buccal canine misalignment of the canine (ranging from 1.5 to 6 mm). The forces released by each wire/bracket/ligature combination with the three different amounts of apical or buccal canine misalignment were tested 20 times. Comparisons between the different types of wire/bracket/ligature systems were carried out by means of analysis of variance on ranks with Dunnett's post hoc test (P < 0.05). No difference in the amount of force released in presence of a misalignment of 1.5 mm was recorded among the three systems. At 3 mm of apical misalignment a significantly greater amount of orthodontic force was released by SLB or SLCB when compared with CLCB, while no significant differences were found among the three systems at 3 mm of buccal canine displacement. When correction of a large amount of misalignment (6 mm) was attempted, a noticeable amount of force for alignment was still generated by the passive SLB and SLCB systems while no force was released in presence of CLCB.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20631083     DOI: 10.1093/ejo/cjq043

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  3 in total

1.  Comparison of friction produced by two types of orthodontic bracket protectors.

Authors:  Steyner de Lima Mendonça; Otávio José Praxedes Neto; Patricia Teixeira de Oliveira; Patricia Bittencourt Dutra dos Santos; Fábio Henrique de Sá Leitão Pinheiro
Journal:  Dental Press J Orthod       Date:  2014 Jan-Feb

2.  Development of a standardized testing system for orthodontic sliding mechanics.

Authors:  Maryam Fathimani; Garrett W Melenka; Dan L Romanyk; Roger W Toogood; Giseon Heo; Jason P Carey; Paul W Major
Journal:  Prog Orthod       Date:  2015-06-04       Impact factor: 2.750

3.  Periodontal effects with self ligating appliances and laser biostimulation.

Authors:  Gianluigi Caccianiga; Giancarlo Cordasco; Alessandro Leonida; Paolo Zorzella; Nadia Squarzoni; Francesco Carinci; Claudia Crestale
Journal:  Dent Res J (Isfahan)       Date:  2012-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.