Literature DB >> 20630181

Potentiometric determination of cetylpyridinium chloride using a new type of screen-printed ion selective electrodes.

Gehad G Mohamed1, Tamer Awad Ali, M F El-Shahat, A M Al-Sabagh, M A Migahed, Elmorsy Khaled.   

Abstract

A new type of screen-printed ion-selective electrode for the determination of cetylpyridinium chloride (CPC) is presented. These new electrodes involve in situ, modified and unmodified screen-printed ion-selective electrodes for the determination of CPC. The screen-printed electrodes (SPEs) show a stable, near-Nernstian response for 1 x 10(-2) to 1 x 10(-6) M CPC at 25 degrees C over the pH range 2-8 with cationic slope 60.66+/-1.10. The lower detection limit is found to be 8 x 10(-7) M and response time of about 3s and exhibit adequate shelf-life (6 months). The fabricated electrodes can be also successfully used in the potentiometric titration of CPC with sodium tetraphenylborate (NaTPB). The analytical performances of the SPEs are compared with those for carbon paste electrode (CPE) and polyvinyl chloride (PVC) electrodes. The method is applied for pharmaceutical preparations with a percentage recovery of 99.60% and R.S.D.=0.53. The frequently used CPC of analytical and technical grade as well as different water samples has been successfully titrated and the results obtained agreed with those obtained with commercial electrode and standard two-phase titration method. The sensitivity of the proposed method is comparable with the official method and ability of field measurements. Copyright 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20630181     DOI: 10.1016/j.aca.2010.05.016

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Potentiometric Surfactant Sensor Based on 1,3-Dihexadecyl-1H-benzo[d]imidazol-3-ium for Anionic Surfactants in Detergents and Household Care Products.

Authors:  Nikola Sakač; Dubravka Madunić-Čačić; Dean Marković; Lucija Hok; Robert Vianello; Bojan Šarkanj; Bojan Đurin; Krunoslav Hajdek; Božo Smoljan; Stjepan Milardović; Brunislav Matasović; Marija Jozanović
Journal:  Molecules       Date:  2021-06-14       Impact factor: 4.411

2.  2,3,5-Triphenyl-2H-tetra-zol-3-ium tetra-phenyl-borate.

Authors:  Hoong-Kun Fun; Tze Shyang Chia; Gamal A E Mostafa; Mohamed M Hefnawy; Hatem A Abdel-Aziz
Journal:  Acta Crystallogr Sect E Struct Rep Online       Date:  2012-07-28

3.  Selective cloud point extraction for the spectrophotometric determination of cetylpyridinium chloride in pharmaceutical formulations.

Authors:  Ali Reza Zarei; Hayedeh Bagheri Sadeghi; Samira Abedin
Journal:  Iran J Pharm Res       Date:  2013       Impact factor: 1.696

4.  Development of Novel Potentiometric Sensors for Determination of Lidocaine Hydrochloride in Pharmaceutical Preparations, Serum and Urine Samples.

Authors:  Tamer Awad Ali; Gehad Genidy Mohamed; Ghada A Yahya
Journal:  Iran J Pharm Res       Date:  2017       Impact factor: 1.696

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.