Literature DB >> 20627691

Sensory testing of spinal anaesthesia for caesarean section: differential block and variability.

M Kocarev1, E Watkins, H McLure, M Columb, G Lyons.   

Abstract

BACKGROUND: The aim of this study was to determine if sensory block following spinal anaesthesia, measured with a range of devices, corresponded to the hierarchy of nerve fibre size in the area of differential block, and to compare the distribution and variability of recorded measurements.
METHODS: Women with singleton pregnancies > 36 weeks of gestation undergoing elective caesarean section under combined spinal-epidural anaesthesia were recruited. An identical spinal anaesthetic was given to all. A single researcher with no clinical role assessed block height at 20 min from the time of spinal injection. Six tests were used in random order to measure four sensory modalities: ethyl chloride (cold), calibrated Neuropen (sharp), standardized monofilament 10 g (pressure), Neurotip stroking (light touch), monofilament stroking (light touch), cotton wool (light touch). The cost of each method of testing was noted.
RESULTS: The median differences between the four modalities were significant (Friedman test, P < 0.0001), but paired tests failed to find significant differences between Neuropen (sharp) and monofilament (pressure), monofilament (pressure) and Neurotip (light touch), and between tests for light touch. The tests for light touch had the least dermatomal spread and produced a unimodal distribution. The coefficient of variation was highest with ethyl chloride (24.1%) and the lowest with cotton wool (10.4%).
CONCLUSIONS: Sensory fibre hierarchy could be identified. Tests for light touch showed the least variability. More expensive tests do not appear to have any advantage over the least expensive test, cotton wool. 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20627691     DOI: 10.1016/j.ijoa.2010.02.002

Source DB:  PubMed          Journal:  Int J Obstet Anesth        ISSN: 0959-289X            Impact factor:   2.603


  3 in total

1.  Evaluation of the accuracy of vibration sense with VibraTip™ as a tool to determine the level of anesthesia following subarachnoid block and its correlation with the pinprick sensation.

Authors:  Sangineni Kalyani Surya Dhana Lakshmi; C Kasavanesi Ramakrishna; Dasari SatyaSree; P Vangala Prakash
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-04-10

2.  Comparison between 10 and 12 mg doses of intrathecal hyperbaric (0.5%) bupivacaine on sensory block level after first spinal failure in cesarean section: A double-blind, randomized clinical trial.

Authors:  Nahid Manouchehrian; Farshid Rahimi-Bashar; Azar Pirdehghan; Fatemeh Shahmoradi
Journal:  Front Med (Lausanne)       Date:  2022-10-04

3.  Prevention and management of intra-operative pain during caesarean section under neuraxial anaesthesia: a technical and interpersonal approach.

Authors:  F Plaat; S E R Stanford; D N Lucas; J Andrade; J Careless; R Russell; D Bishop; Q Lo; D Bogod
Journal:  Anaesthesia       Date:  2022-03-24       Impact factor: 12.893

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.