Literature DB >> 20625787

Effects of heating by steam autoclaving and Er:YAG laser etching on dentin components.

Luís Eduardo S Soares1, Aldo Brugnera, Fátima A A Zanin, Ana Maria E Santo, Airton A Martin.   

Abstract

The simultaneous need for infection-control protocols in sample preparations and for safe laser irradiation parameters prompted this study about the effects of heat produced by both sample sterilization and laser etching on dentin components. The dentin was exposed on 30 bovine incisors, and then divided into two main groups: autoclaved (group A) or thymol treatment (group B). The surface of the dentin was schematically divided into four areas, with each one corresponding to a treatment subgroup. The specimens were either etched with phosphoric acid (control-CG) or irradiated with Er:YAG laser (subgroups: I-80 mJ, II-120 mJ, and III-180 mJ). Elemental distribution maps were done by energy-dispersive X-ray fluorescence (μ-EDXRF) on each treatment area. The dentin surface in depth was exposed and line-scan maps were performed. The B_CG treatment produced the best distribution of calcium (Ca) and phosphorus (P) content throughout the dentin surface. Er:YAG laser etching produced irregular patterns of elemental distribution in the dentin. Laser energies of 120 and 180 mJ produced the highest maximum calcium values. The Er:YAG laser energy of 180 mJ produced a localized increase in Ca and P content on the superficial layer of the dentin (∼ 0-0.10 mm). The autoclaving treatment of samples in experiments is not recommended since it produced damaging effects on dentin components. Er:YAG laser irradiation produced a heterogeneous Ca and P distribution throughout the dentin surface with areas of increased Ca concentration, and this may affect clinically the permeability, solubility, or adhesive characteristics of dental hard tissues with restorative procedures.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20625787     DOI: 10.1007/s10103-010-0814-9

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  22 in total

1.  Ultrastructural properties of laser-irradiated and heat-treated dentin.

Authors:  R Rohanizadeh; R Z LeGeros; D Fan; A Jean; G Daculsi
Journal:  J Dent Res       Date:  1999-12       Impact factor: 6.116

2.  Effects of Er:YAG laser irradiation on human dentin: polarizing microscopic, light microscopic and microradiographic observations, and FT-IR analysis.

Authors:  Yaeko Ishizaka; Toru Eguro; Toru Maeda; Hisayoshi Tanaka
Journal:  Lasers Surg Med       Date:  2002       Impact factor: 4.025

3.  Er:YAG laser treatments on dentine surface: micro-Raman spectroscopy and SEM analysis.

Authors:  C Camerlingo; M Lepore; G M Gaeta; R Riccio; C Riccio; A De Rosa; M De Rosa
Journal:  J Dent       Date:  2004-07       Impact factor: 4.379

4.  Ultramorphological and histochemical changes after ER,CR:YSGG laser irradiation and two different irrigation regimes.

Authors:  Emre Altundasar; Bahar Ozçelik; Zafer C Cehreli; Koukichi Matsumoto
Journal:  J Endod       Date:  2006-05       Impact factor: 4.171

5.  Effect of different laser devices on the composition and microhardness of dentin.

Authors:  Esra Uzer Celik; Zeynep Ergücü; L Sebnem Türkün; Murat Türkün
Journal:  Oper Dent       Date:  2008 Sep-Oct       Impact factor: 2.440

6.  Effect of sterilization by gamma radiation on nano-mechanical properties of teeth.

Authors:  Delia S Brauer; Kuniko Saeki; Joan F Hilton; Grayson W Marshall; Sally J Marshall
Journal:  Dent Mater       Date:  2008-04-23       Impact factor: 5.304

7.  The effect of steam sterilization on the physical properties and perceived cutting characteristics of extracted teeth.

Authors:  D E Parsell; B M Stewart; J R Barker; T G Nick; L Karns; R B Johnson
Journal:  J Dent Educ       Date:  1998-03       Impact factor: 2.264

8.  Experimental studies of the application of the Er:YAG laser on dental hard substances: II. Light microscopic and SEM investigations.

Authors:  U Keller; R Hibst
Journal:  Lasers Surg Med       Date:  1989       Impact factor: 4.025

9.  Experimental studies of the application of the Er:YAG laser on dental hard substances: I. Measurement of the ablation rate.

Authors:  R Hibst; U Keller
Journal:  Lasers Surg Med       Date:  1989       Impact factor: 4.025

10.  Evaluation of mineral content of dentin prepared by erbium, chromium:yttrium scandium gallium garnet laser.

Authors:  Asli Secilmis; Subutayhan Altintas; Aslihan Usumez; Gizem Berk
Journal:  Lasers Med Sci       Date:  2007-10-20       Impact factor: 3.161

View more
  4 in total

1.  Effects of two disinfection/sterilization methods for dentin specimens on dentin permeability.

Authors:  Ruodan Jiang; Yongxiang Xu; Hong Lin
Journal:  Clin Oral Investig       Date:  2018-06-14       Impact factor: 3.573

Review 2.  A critical analysis of research methods and experimental models to study irrigants and irrigation systems.

Authors:  Christos Boutsioukis; Maria Teresa Arias-Moliz; Luis E Chávez de Paz
Journal:  Int Endod J       Date:  2022-03-06       Impact factor: 5.165

3.  Molecular and morphological surface analysis: effect of filling pastes and cleaning agents on root dentin.

Authors:  Vanessa Benetello Dainezi; Alexsandra Shizue Iwamoto; Airton Abrahão Martin; Luís Eduardo Silva Soares; Yumiko Hosoya; Fernanda Miori Pascon; Regina Maria Puppin-Rontani
Journal:  J Appl Oral Sci       Date:  2017 Jan-Feb       Impact factor: 2.698

4.  Peracetic Acid: A Practical Alternative to Formalin for Disinfection of Extracted Human Teeth.

Authors:  Riaz Ali; Justin Bartholomew; Randolph Coffey; Caroline Carrico; Todd Kitten; Parthasarathy Madurantakam
Journal:  Bioengineering (Basel)       Date:  2021-12-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.