The value of aspherizing intraocular lens surfaces for the purpose of improving retinal image quality of pseudophakic eyes was investigated. Surfaces were made as conicoids. Changes in primary wave aberrations and refractive errors were found to be proportional to changes in surface asphericity. The optimum asphericity depends markedly on ocular parameters, lens fitting position and how well lenses are centred within the eye. If lenses are not well centred, the asphericity that eliminates spherical aberration may result in poorer performance than that occurring with spherical surfaces. It is suggested that there is no general benefit in aspherizing surfaces of intraocular lenses.

Mesh:

Year:  1991        PMID: 2062538     DOI: 10.1111/j.1475-1313.1991.tb00213.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  10 in total

1.  [Clinical results of the aspheric intraocular lens FY-60AD (Hoya) with particular respect to decentration and tilt].

Authors:  U Mester; S Heinen; H Kaymak
Journal:  Ophthalmologe       Date:  2010-09       Impact factor: 1.059

2.  Wavefront analysis of acrylic spherical and aspherical intraocular lenses.

Authors:  Satoru Takeo; Yoichiro Watanabe; Misa Suzuki; Kazuaki Kadonosono
Journal:  Jpn J Ophthalmol       Date:  2008-09-05       Impact factor: 2.447

3.  Temporal multiplexing with adaptive optics for simultaneous vision.

Authors:  Eleni Papadatou; Antonio J Del Águila-Carrasco; Iván Marín-Franch; Norberto López-Gil
Journal:  Biomed Opt Express       Date:  2016-09-15       Impact factor: 3.732

4.  In vitro optical performance of a new aberration-free intraocular lens.

Authors:  D Madrid-Costa; J Ruiz-Alcocer; T Ferrer-Blasco; S García-Lázaro; R Montés-Micó
Journal:  Eye (Lond)       Date:  2014-02-21       Impact factor: 3.775

5.  [Aspheric optics: physical fundamentals].

Authors:  M Mrochen; M Büeler
Journal:  Ophthalmologe       Date:  2008-03       Impact factor: 1.059

6.  Visual performance of the Tecnis one-piece lens ZCB00.

Authors:  Sherein S Wahba; Riad F Riad; Fathy F Morkos; Abdallah K Hassouna; Maged M Roshdy
Journal:  Clin Ophthalmol       Date:  2011-12-23

7.  Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye.

Authors:  Takashi Fujikado; Makoto Saika
Journal:  Clin Ophthalmol       Date:  2014-11-28

8.  Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO.

Authors:  Ahmad-Reza Baghi; Mohammad-Reza Jafarinasab; Hossein Ziaei; Zahra Rahmani
Journal:  J Ophthalmic Vis Res       Date:  2008-01

9.  Comparison of retinal image quality with spherical and customized aspheric intraocular lenses.

Authors:  Huanqing Guo; Alexander V Goncharov; Chris Dainty
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732

10.  Comparison of Anterior Corneal Aberrometry, Keratometry and Pupil Size with Scheimpflug Tomography and Ray Tracing Aberrometer.

Authors:  Zahra Ashena; Sean Gallagher; Hasan Naveed; David J Spalton; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2022-03-18
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.