Literature DB >> 20625184

Performing slow vital capacity in older people with and without cognitive impairment--is it useful?

S C Allen1, C Charlton, W Backen, M Warwick-Sanders, P Yeung.   

Abstract

BACKGROUND: most patients with moderate cognitive impairment are unable to perform forced spirometry. It has been suggested that slow vital capacity (SVC) is easier to perform than forced vital capacity (FVC) because it requires less understanding and co-ordination. We conducted a study to determine whether that assertion is correct.
METHODS: we studied 83 inpatients, mean age 83 years (range 67-95, 51 female). They had measurements made of FVC, SVC and the Mini-Mental State Examination (MMSE). The spirometry was conducted using the European Respiratory Society/American Thoracic Society standards.
RESULTS: of the 83 subjects, 38 were able to do both FVC and SVC and 32 were unable to do either. The overall concordance was 84%. Twelve were able to do SVC but not FVC (eight due to excessive cough, two due to weakness and two had an MMSE < 24 with poor co-ordination). An inability to do neither FVC nor SVC was predicted by an MMSE < 24/30 (P < 0.0001) with a sensitivity of 88% and specificity of 67%.
CONCLUSION: SVC is not a usable substitute for FVC for elderly patients with cognitive impairment but is of some utility for those who tend to cough. An MMSE < 24/30 is predictive of inability to perform FVC and SVC.

Entities:  

Mesh:

Year:  2010        PMID: 20625184     DOI: 10.1093/ageing/afq084

Source DB:  PubMed          Journal:  Age Ageing        ISSN: 0002-0729            Impact factor:   10.668


  5 in total

1.  Outcome measures in amyotrophic lateral sclerosis clinical trials.

Authors:  Sabrina Paganoni; Merit Cudkowicz; James D Berry
Journal:  Clin Investig (Lond)       Date:  2014

Review 2.  The importance of the assessment of pulmonary function in COPD.

Authors:  Kristina L Bailey
Journal:  Med Clin North Am       Date:  2012-05-31       Impact factor: 5.456

3.  Predictors of poor-quality spirometry in two cohorts of older adults in Russia and Belgium: a cross-sectional study.

Authors:  Eralda Turkeshi; Dmitry Zelenukha; Bert Vaes; Elena Andreeva; Elena Frolova; Jean-Marie Degryse
Journal:  NPJ Prim Care Respir Med       Date:  2015-07-23       Impact factor: 2.871

4.  Relationship between lung function and grip strength in older hospitalized patients: a pilot study.

Authors:  Sarah J Holmes; Stephen C Allen; Helen C Roberts
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2017-04-19

5.  Spirometry reference values in the Brazilian population.

Authors:  R Rufino; C H Costa; A J Lopes; A I Maiworm; K Maynard; L M R A Silva; R M Dias
Journal:  Braz J Med Biol Res       Date:  2017-03-02       Impact factor: 2.590

  5 in total