Literature DB >> 2062217

Acute myocardial infarction: comparison of T2-weighted and T1-weighted gadolinium-DTPA enhanced MR imaging.

N A Matheijssen1, A de Roos, E E van der Wall, J Doornbos, P R van Dijkman, A V Bruschke, A E van Voorthuisen.   

Abstract

Magnetic resonance images were obtained from 32 patients with acute myocardial infarction, using a four-echo technique (echo time (TE) = 30, 60, 90, and 120 ms) pregadolinium(Gd)-DTPA injection and a TE = 30 ms sequence pre- and post-Gd-DTPA. Intensity ratios of infarcted and normal myocardium were calculated, as were contrast-to-noise and signal-to-noise ratios. The four intensity ratios pre-Gd-DTPA were 1.20 +/- 0.15, 1.42 +/- 0.22, 1.78 +/- 0.38, and 1.99 +/- 0.60 for TE = 30, 60, 90, and 120 ms, respectively, and 1.42 +/- 0.19 post-Gd-DTPA (p = NS for post-Gd-DTPA vs TE = 60, p = 0.007 for TE = 90 vs TE = 120, p less than 0.0001 for all other comparisons). The four contrast-to-noise ratios pre-Gd-DTPA were 1.69 +/- 0.97, 2.69 +/- 1.13, 3.17 +/- 1.15, and 2.90 +/- 1.09 for TE = 30, 60, 90, and 120 ms, respectively, and 2.71 +/- 1.26 post-Gd-DTPA (p = NS for post-Gd-DTPA vs TE = 60, 90, and 120, p = NS for TE = 120 vs TE = 60 and 90, p less than 0.01 for all other comparisons). The four signal-to-noise ratios pre-Gd-DTPA were 8.67 +/- 1.47, 6.52 +/- 0.76, 5.20 +/- 0.64, 4.17 +/- 0.53 for TE = 30, 60, 90, and 120 ms, respectively, and 9.17 +/- 1.92 post-Gd-DTPA (p = 0.03 for post-Gd-DTPA vs TE = 30, p less than 0.0001 for all other comparisons). In conclusion, the detectabilities of acute myocardial infarction were similar at TE = 60 ms and at Gd-DTPA enhanced short-TE MR imaging. However, image quality proved to be superior using the Gd-DTPA enhanced short-TE technique.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2062217     DOI: 10.1002/mrm.1910170217

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Localization and determination of infarct size by Gd-Mesoporphyrin enhanced MRI in dogs.

Authors:  P Herijgers; S K Laycock; Y Ni; G Marchal; J Bogaert; H Bosmans; C Petré; W Flameng
Journal:  Int J Card Imaging       Date:  1997-12

2.  Echocardiography in Takotsubo cardiomyopathy; a useful approach?

Authors:  E E van der Wall; E R Holman; A J Scholte; J J Bax
Journal:  Int J Cardiovasc Imaging       Date:  2010-06       Impact factor: 2.357

3.  Tissue characterization in Takotsubo cardiomyopathy; a valuable approach?

Authors:  E E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

4.  Stress imaging in patients with diabetes; routine practice?

Authors:  E E van der Wall; A J Scholte; E R Holman; J J Bax
Journal:  Int J Cardiovasc Imaging       Date:  2010-05-08       Impact factor: 2.357

  4 in total