Literature DB >> 20621431

Mammography image quality: model for predicting compliance with posterior nipple line criterion.

Kelly Spuur1, Wai Tak Hung, Ann Poulos, Mary Rickard.   

Abstract

PURPOSE: To develop a model using measurements of pectoral muscle width and length together with the acceptability of the posterior nipple line criteria (PNL) to predict the acceptability of the presentation of the pectoral muscle in the mediolateral oblique view of the breast.
METHOD: A total of 400 mediolateral oblique mammogram images were randomly selected from BreastScreen NSW South West, Australia. Measurements of length and width of the pectoral muscle and the acceptability of the pectoral muscle position relative to the PNL were recorded. Data analysis involved logistic regression and ROC analysis to test the predictors of width and length and the performance of the model. The model was then used to predict the outcome of acceptable or unacceptable PNL criterion for each case.
RESULTS: The estimated odds ratio for an increase of 10mm was 1.98 (CI=1.68, 2.34) for the length predictor and 2.14 (CI=1.56, 2.93) for the width predictor. A cut off point of 0.6083 was derived from the training set and applied with the developed model to the test set. The area under the ROC curve was 0.9339 demonstrating an accurate model.
CONCLUSION: This paper describes a model to predict the acceptability of the PNL criterion using the width and length of the pectoral muscle. This model could be used in the automated assessment of image quality which has the potential to enhance the consistency in mammographic image quality evaluation. Optimising image quality contributes to increased accuracy in radiological interpretation, which maximises the early detection of breast cancer and potentially reduces mortality rates.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20621431     DOI: 10.1016/j.ejrad.2010.06.026

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  4 in total

1.  Practitioner compression force variability in mammography: a preliminary study.

Authors:  C E Mercer; P Hogg; R Lawson; J Diffey; E R E Denton
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

2.  Full-field digital mammography: the '30% rule' and influences on visualisation of the pectoralis major muscle on the craniocaudal view of the breast.

Authors:  Julia Strohbach; Jenny Maree Wilkinson; Kelly Maree Spuur
Journal:  J Med Radiat Sci       Date:  2020-06-22

3.  Overview of the radiographers' practice in 65 healthcare centers using digital mammography systems in Portugal.

Authors:  Cláudia Sá Dos Reis; Ana Pascoal; Lucian Radu; Mário Fartaria de Oliveira; João Alves
Journal:  Insights Imaging       Date:  2017-03-16

4.  Study of breast implants mammography examinations for identification of suitable image quality criteria.

Authors:  Cláudia Sá Dos Reis; Isabelle Gremion; Nicole Richli Meystre
Journal:  Insights Imaging       Date:  2020-01-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.