Literature DB >> 20620695

Sonomyography (SMG) control for powered prosthetic hand: a study with normal subjects.

Xin Chen1, Yong-Ping Zheng, Jing-Yi Guo, Jun Shi.   

Abstract

Our previous studies have demonstrated that the muscle thickness change detected by ultrasonography during contraction, namely sonomyography (SMG), can be used for functional assessment of skeletal muscles and has the potential for prosthetic control. In this study, we further investigated the feasibility of using one-dimensional SMG (1-D SMG) signal for controlling a powered prosthesis with one degree of freedom. The performance of SMG control in visual pursuit tracking of opening-closure patterns of the prosthesis was evaluated. Nine normal subjects including seven males and two females participated in the experiment. SMG signals were collected from the extensor carpi radialis muscle to control the opening position of the prosthetic hand. The subjects were instructed to perform the wrist extension movement to match the prosthesis response to the target sinusoid and square tracks under different movement rates as accurately as possible. The normalized root mean square (RMS) tracking error between the target track and the degree of the prosthetic hand's opening position, which was measured by an electronic goniometer, was calculated to evaluate the control performance. It was found that the mean RMS tracking errors of SMG control under different movement rates were 12.8 +/- 3.2% (mean +/- SD) and 14.8 +/- 4.6% for sinusoid and square tracks, respectively. Two-way analysis of variance (ANOVA) revealed significant differences in RMS tracking errors among the three movement rates (p = 2.0 x 10(-6)) and between the two target tracks (p = 0.007). The results suggest that SMG signal, based on further improvement, has potential to be an alternative method for prosthetic control. Copyright 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2010        PMID: 20620695     DOI: 10.1016/j.ultrasmedbio.2010.04.015

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  9 in total

1.  Sonomyographic responses during voluntary isometric ramp contraction of the human rectus femoris muscle.

Authors:  Xin Chen; Yong-Ping Zheng; Jing-Yi Guo; Zhenyu Zhu; Shing-Chow Chan; Zhiguo Zhang
Journal:  Eur J Appl Physiol       Date:  2011-11-13       Impact factor: 3.078

2.  Classification Performance and Feature Space Characteristics in Individuals With Upper Limb Loss Using Sonomyography.

Authors:  Susannah Engdahl; Ananya Dhawan; Ahmed Bashatah; Guoqing Diao; Biswarup Mukherjee; Brian Monroe; Rahsaan Holley; Siddhartha Sikdar
Journal:  IEEE J Transl Eng Health Med       Date:  2022-01-06       Impact factor: 3.316

3.  First Demonstration of Functional Task Performance Using a Sonomyographic Prosthesis: A Case Study.

Authors:  Susannah M Engdahl; Samuel A Acuña; Erica L King; Ahmed Bashatah; Siddhartha Sikdar
Journal:  Front Bioeng Biotechnol       Date:  2022-05-04

Review 4.  Non-invasive control interfaces for intention detection in active movement-assistive devices.

Authors:  Joan Lobo-Prat; Peter N Kooren; Arno H A Stienen; Just L Herder; Bart F J M Koopman; Peter H Veltink
Journal:  J Neuroeng Rehabil       Date:  2014-12-17       Impact factor: 4.262

5.  A realistic implementation of ultrasound imaging as a human-machine interface for upper-limb amputees.

Authors:  David Sierra González; Claudio Castellini
Journal:  Front Neurorobot       Date:  2013-10-22       Impact factor: 2.650

6.  A comparative analysis of three non-invasive human-machine interfaces for the disabled.

Authors:  Vikram Ravindra; Claudio Castellini
Journal:  Front Neurorobot       Date:  2014-10-27       Impact factor: 2.650

Review 7.  Perspective and Evolution of Gesture Recognition for Sign Language: A Review.

Authors:  Jesús Galván-Ruiz; Carlos M Travieso-González; Acaymo Tejera-Fettmilch; Alejandro Pinan-Roescher; Luis Esteban-Hernández; Luis Domínguez-Quintana
Journal:  Sensors (Basel)       Date:  2020-06-24       Impact factor: 3.576

8.  Ultrasound Measurement of Skeletal Muscle Contractile Parameters Using Flexible and Wearable Single-Element Ultrasonic Sensor.

Authors:  Ibrahim AlMohimeed; Yuu Ono
Journal:  Sensors (Basel)       Date:  2020-06-27       Impact factor: 3.576

9.  Classifying Muscle States with One-Dimensional Radio-Frequency Signals from Single Element Ultrasound Transducers.

Authors:  Lukas Brausch; Holger Hewener; Paul Lukowicz
Journal:  Sensors (Basel)       Date:  2022-04-05       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.