Bowel preparation suitable for same-day computed tomography colonography and colonoscopy.

Maggie Eddy1, Giles Stevenson, John Mathieson, Carola Behrens, Richard Eddy.   

Abstract

PURPOSE: This study was designed to evaluate whether a bowel preparation used for computed tomography (CT) colonography could also be suitable for same-day colonoscopy regardless of which test was done first.
METHOD: Six different endoscopists working at 3 separate hospitals evaluated 75 patients who underwent colonoscopy after receiving a bowel preparation that contained contrast material used to tag fecal and fluid material to facilitate CT colonography. This bowel preparation has been used in more than 1500 CT colonography studies. Evaluation included assessment of whether the colon was clean and dry, and whether the contrast material caused any impairment of visualization or clogging of the endoscopes. Some of the patients had first undergone CT colonography followed by same-day colonoscopy, whereas other patients had colonoscopy as their initial test.
RESULTS: Although the contrast material was sometimes perceptible, the volumes were very small, and caused no impairment of mucosal visualization and no clogging of the endoscopes. The bowel preparation was well tolerated. Same-day CT colonography and colonoscopy with fecal tagging was technically possible.
CONCLUSION: A simple, fairly low cost 1-day bowel preparation with fluid and fecal tagging is suitable for CT colonography and colonoscopy done the same day in either order. However, the preferences of individual endoscopists and difficulties with making oral contrast agents readily available are challenges to widespread adoption of a common bowel preparation regimen.
Copyright © 2011 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20619596     DOI: 10.1016/j.carj.2010.05.003

Source DB:  PubMed          Journal:  Can Assoc Radiol J        ISSN: 0846-5371            Impact factor:   2.248


  2 in total

1.  The safety of same-day CT colonography following incomplete colonoscopy with polypectomy.

Authors:  Luis F Lara; Danny Avalos; Huan Huynh; Brenda Jimenez-Cantisano; Mariann Padron; Ronnie Pimentel; Tolga Erim; Alison Schneider; Andrew Ukleja; Albert Parlade; Fernando Castro
Journal:  United European Gastroenterol J       Date:  2015-08       Impact factor: 4.623

2.  Objective and Subjective Intrapatient Comparison of Iohexol Versus Diatrizoate for Bowel Preparation Quality at CT Colonography.

Authors:  Brandon Johnson; J Louis Hinshaw; Jessica B Robbins; Perry J Pickhardt
Journal:  AJR Am J Roentgenol       Date:  2016-03-24       Impact factor: 3.959

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.